Evidence map›Paper›PMID 38066732›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis.

Loris Lahuna, Joël Greffier, Jean Goupil, Julien Frandon, Maxime Pastor, Fabien De Oliveira, Jean Paul Beregi, Djamel Dabli

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Loris LahunaDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Joël GreffierDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0002-1735-5129
Jean GoupilDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0001-6238-102X
Julien FrandonDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0001-7816-8178
Maxime PastorDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Fabien De OliveiraDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Jean Paul BeregiDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Djamel DabliDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0003-1003-1196
Université de Montpellier · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Images from 64 patients undergoing an enhanced abdominal-pelvis scan at portal phase in dual-energy CT mode for the diagnosis of colitis or bowel obstruction were retrospectively analyzed. Acquisitions were performed on a third-generation dual-source CT (DSCT) 100/Sn150 kVp. Mixed images were generated, as well as virtual monoenergetic images (VMIs) at 40/50/60/70 keV. Objective image quality was assessed on VMIs and mixed images by measuring contrast, noise and contrast-to-noise ratio (CNR). Noise, smoothing and overall image quality were subjectively analyzed by two radiologists using Likert scales. For both patient groups, the noise decreased significantly according to the energy level from 40 to 60 keV by -47.2 ± 24.0% for bowel obstruction and -50.4 ± 18.2% for colitis. It was similar between 60 and 70 keV (

Indexed as

bowel obstructioncolitisdual-energy CTdual-source CTvirtual monoenergetic images

Identifiers

PMID38066732
PMCPMC10705951
OpenAlexW4388866235

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.