Evidence map›Paper›PMID 38066608›Full record

ArticleEuropean journal of medical research2023

Comparison of different internal fixation models in ankle arthrodesis using 3D finite-element analysis.

Bo Feng, Qing-Bo Gao, Guang-Ming Dai, Ke-Cheng Niu, Wei Jiang, Zhen-Yu Wang, Hao-Yan Zheng

Open access · goldAbstract read
In one paragraph

Article in European journal of medical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Bo Feng *Department of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China. fengbofb9@126.com.
Qing-Bo Gao *Department of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Guang-Ming DaiDepartment of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Ke-Cheng NiuDepartment of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Wei JiangDepartment of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Zhen-Yu WangDepartment of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Hao-Yan ZhengDepartment of Orthopaedic Medicine, Third Affiliated Hospital of Inner Mongonia Medical University, No.20 of Shaoxian Road, Kundulun District, Baotou, 014010, China.
Third Affiliated Hospital of Inner Mongolia Medical College · CN

Funding

Health Project of Metallurgical Medicine and Safety Branch of Chinese Metal Society jkws202051
6 · The paper itself

Abstract

backgroundThe purpose of this study is to use three-dimensional finite-element analysis to better understand the biomechanical features of various internal fixators for ankle arthrodesis.

methodsWe used finite-element analysis to compare four different types of internal fixations in ankle arthrodesis: Group A had three crossed screws (Ø6.5 mm); Group B had two crossed screws (Ø6.5 mm) and an anterior plate (Ø2.7 mm); Group C only had an anterior anatomical plate (Ø3.5 mm); Group D had one anterior anatomical plate (Ø3.5 mm) and one posterior-lateral screw (Ø6.5 mm). We adopted Ansys 21.0 software to analyze and compare the four types in terms of the displacement of the arthrodesis surface and the stress peak and stress distribution of these models under intorsion, extorsion, dorsiflexion torque, and neutral vertical load.

results① Displacement of the arthrodesis surface: In Group A, the maximum displacement was larger than Group D under neutral vertical load and dorsiflexion torque but less than it under intorsion and extorsion torque. In Group B, the maximum displacement against dorsiflexion, neutral vertical load, intorsion, and extorsion was less than that in the other three fixation models. In Group C, the maximum displacement against the above four loading patterns were significantly higher than that in another three fixation models. ② Stress peak and stress distribution: based on the stress distribution of the four models, the peak von Mises stress was concentrated in the central sections of the compression screws, plate joints, and bending parts of the plates.

conclusionsThe fixation model consisting of two crossed screws and an anterior outperformed the other three fixation models in terms of biomedical advantages; thus, this model can be deemed a safe and reliable internal fixation approach for ankle arthrodesis.

Indexed as

AnkleAnkle JointArthrodesisBiomechanical PhenomenaBone PlatesFracture Fixation, InternalHumans3D finite elementAnkle arthrodesisBiomechanicsDigital orthopedicsInternal fixation

Identifiers

PMID38066608
PMCPMC10704803
OpenAlexW4389486247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.