Early outcomes of total hip arthroplasty using point-of-care manufactured patient-specific instruments: a single university hospital's initial experience.

Hieu Pham Trung, Nang Vo Sy Quyen, Nam Vu Tu, Dung Tran Trung, Toan Duong Dinh

Erratum issuedAbstract read
In one paragraph

Article in BMC surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. [Hip surgery: 3D printed implants in revision arthroplasty].Orthopadie (Heidelberg, Germany) · 2025
    Review
  6. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Hieu Pham TrungHanoi Medical University, Hanoi, Vietnam.
Nang Vo Sy QuyenHanoi Medical University, Hanoi, Vietnam.
Nam Vu TuCenter for Orthopedics and Sports Medicine, Vinmec Healthcare System, Hanoi, Vietnam.
Dung Tran TrungCenter for Orthopedics and Sports Medicine, Vinmec Healthcare System, Hanoi, Vietnam.
Toan Duong DinhHanoi Medical University, Hanoi, Vietnam. duongdinhtoan@hmu.edu.vn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of 3D-printed Patient-Specific Instruments (PSI) has been investigated to enhance the postoperative functional results in total hip arthroplasty (THA) and has been recognized as an innovative approach for the optimal alignment of hip implant components. Point-of-care production is gradually becoming the norm for PSI manufacturing. The purpose of this article is to assess the accuracy and safety of PSI for total hip arthroplasty performed at the point-of-care in Vietnam.

methods34 THA cases were assessed in this prospective study. A template for the size and orientation of the implant and the design of the PSI was generated using data from preoperative 3D computed tomography (CT) scanning of the lower limb. The principal surgeon determined the implants' position and PSI design directly using the software. The PSI is then produced using a 3D-compatible resin printer in our manufacturing hospital. The PSI, consisting of an acetabulum and a femoral component placed press-fit on the bony surface, guided surgeons to precisely ream the acetabulum and cut the femoral neck according to the pre-planned plane. Postoperative CT scanning was obtained and superimposed onto the 3D model of the implant to evaluate the accuracy of the procedure by comparing the orientation values of the cup and the alignment of the stem between the planned and the actual results. Intra- and postoperative clinical parameters of surgery, including surgical time, intra-operative blood loss, complications, and the first ambulation, were also recorded to evaluate the safety of the surgery.

resultsThe preparation for PSI required an average of 3 days. 94% of cup size and 91% of stem size were correctly selected. The mean values of postoperative inclination and anteversion were 44.2° ± 4.1° and 19.2° ± 5.6°, respectively. 64.7% of cases deviated from planned within the ± 5

conclusionsThe point-of-care manufactured PSI is a useful solution for improving the accuracy of total hip arthroplasty surgery, especially in restoring implant orientation and reducing leg length discrepancy. However, long-term clinical follow-up evaluation is needed to confirm the efficacy and safety of this approach.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisBlood Loss, SurgicalHumansPoint-of-Care SystemsProspective StudiesTomography, X-Ray Computed3D PrintingPatient-specific instrumentPoint-of-care manufacturingPSITHATotal hip arthroplasty

Identifiers

PMID38066450
PMCPMC10704642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.