Evidence map›Paper›PMID 38066193›Full record

ArticleSurgical endoscopy2024

A generic scope actuation system for flexible endoscopes.

Sofia Basha, Mohammad Khorasani, Nihal Abdurahiman, Jhasketan Padhan, Victor Baez, Abdulla Al-Ansari, Panagiotis Tsiamyrtzis, Aaron T Becker, Nikhil V Navkar

Open access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Evaluation of User Interfaces for Actuated Control of Endoscopes During Flexible Endoscopy.IEEE journal of translational engineering in health and medicine · 2026
    Article
  2. An Actuated Variable-View Rigid Scope System to Assist Visualization in Diagnostic Procedures.IEEE journal of translational engineering in health and medicine · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 4 countries.

Sofia BashaDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar.
Mohammad KhorasaniDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar.
Nihal AbdurahimanDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar.
Jhasketan PadhanDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar.
Victor BaezDepartment of Electrical Engineering, University of Houston, Houston, TX, USA.
Abdulla Al-AnsariDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar.
Panagiotis TsiamyrtzisDepartment of Mechanical Engineering, Politecnico Di Milano, Milan, Italy.
Aaron T BeckerDepartment of Electrical Engineering, University of Houston, Houston, TX, USA.
Nikhil V NavkarDepartment of Surgery, Hamad Medical Corporation, Doha, Qatar. nnavkar@hamad.qa.ORCID http://orcid.org/0000-0003-1853-1910
Hamad Medical Corporation · QAUniversity of Houston · USAthens University of Economics and Business · GR

Funding

Qatar National Research Fund NPRP13S-0116-200084
6 · The paper itself

Abstract

backgroundA scope actuation system assists a surgeon in steering a scope for navigating an operative field during an interventional or diagnostic procedure. Each system is tailored for a specific surgical procedure. The development of a generic scope actuation system could assist various laparoscopic and endoscopic procedures. This has the potential to reduce the deployment and maintenance costs for a hospital, making it more accessible for clinical usage.

methodsA modular actuation system (for maneuvering rigid laparoscopes) was adapted to enable incorporation of flexible endoscopes. The design simplifies the installation and disassembly processes. User studies were conducted to assess the ability of the system to focus onto a diagnostic area, and to navigate during a simulated esophagogastroduodenoscopy procedure. During the studies, the endoscope was maneuvered with (robotic mode) and without (manual mode) the actuation system to navigate the endoscope's focus on a predefined track.

resultsResults show that the robotic mode performed better than the manual mode on all the measured performance parameters including (a) the total duration to traverse a track, (b) the percentage of time spent outside a track while traversing, and (c) the number of times the scope focus shifts outside the track. Additionally, robotic mode also reduced the perceived workload based on the NASA-TLX scale.

conclusionsThe proposed scope actuation system enhances the maneuverability of flexible endoscopes. It also lays the groundwork for future development of modular and generic scope assistant systems that can be used in both laparoscopic and endoscopic procedures.

Indexed as

LaparoscopyRoboticsEndoscopesEquipment DesignHumansLaparoscopesActuationEndoscopyRobotic controlSurgical endoscopeVisualization

Identifiers

PMID38066193
PMCPMC10830823
OpenAlexW4389491228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.