ArticleAnnals of biomedical engineering2024
Super-Resolution Reconstruction of CT Images Based on Multi-scale Information Fused Generative Adversarial Networks.
Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- AI-ChatGPT/GPT-4: An Booster for the Development of Physical Medicine and Rehabilitation in the New Era!Annals of biomedical engineering · 2024Article
- Revolutionary Potential of ChatGPT in Constructing Intelligent Clinical Decision Support Systems.Annals of biomedical engineering · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The popularization and widespread use of computed tomography (CT) in the field of medicine evocated public attention to the potential radiation exposure endured by patients. Reducing the radiation dose may lead to scattering noise and low resolution, which can adversely affect the radiologists' judgment. Hence, this paper introduces a new network called PANet-UP-ESRGAN (PAUP-ESRGAN), specifically designed to obtain low-dose CT (LDCT) images with high peak signal-to-noise ratio (PSNR) and high resolution (HR). The model was trained on synthetic medical image data based on a Generative Adversarial Network (GAN). A degradation modeling process was introduced to accurately represent realistic degradation complexities. To reconstruct image edge textures, a pyramidal attention model call PANet was added before the middle of the multiple residual dense blocks (MRDB) in the generator to focus on high-frequency image information. The U-Net discriminator with spectral normalization was also designed to improve its efficiency and stabilize the training dynamics. The proposed PAUP-ESRGAN model was evaluated on the abdomen and lung image datasets, which demonstrated a significant improvement in terms of robustness of model and LDCT image detail reconstruction, compared to the latest real-esrgan network. Results showed that the mean PSNR increated by 19.1%, 25.05%, and 21.25%, the mean SSIM increated by 0.4%, 0.4%, and 0.4%, and the mean NRMSE decreated by 0.25%, 0.25%, and 0.35% at 2[Formula: see text], 4[Formula: see text], and 8[Formula: see text] super-resolution scales, respectively. Experimental results demonstrate that our method outperforms the state-of-the-art super-resolution methods on restoring CT images with respect to peak signal-to-noise ratio (PSNR), structural similarity (SSIM) and normalized root-mean-square error (NRMSE) indices.
Indexed as
Identifiers
38064116What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.