Evidence map›Paper›PMID 38062094›Full record

ArticleScientific reports2023

Modified medial minimally invasive double-plating osteosynthesis techniques for the treatment of distal third diaphyseal fracture of humerus.

Youyou Ye, Yanbin Lin, Chunling Wu, Yunzhe Zhu

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Youyou YeDepartment of Traumatic Orthopaedics, Fuzhou Second Hospital, The Third Clinical Medical College, Fujian Medical University, 47th Shangteng Road of Cangshan District, Fuzhou, 350007, Fujian, China.
Yanbin LinDepartment of Traumatic Orthopaedics, Fuzhou Second Hospital, The Third Clinical Medical College, Fujian Medical University, 47th Shangteng Road of Cangshan District, Fuzhou, 350007, Fujian, China. 746001548@qq.com.
Chunling WuDepartment of Traumatic Orthopaedics, Fuzhou Second Hospital, The Third Clinical Medical College, Fujian Medical University, 47th Shangteng Road of Cangshan District, Fuzhou, 350007, Fujian, China.
Yunzhe ZhuDepartment of Traumatic Orthopaedics, Fuzhou Second Hospital, The Third Clinical Medical College, Fujian Medical University, 47th Shangteng Road of Cangshan District, Fuzhou, 350007, Fujian, China.

Funding

Fujian Provincial Clinical Medical Research Center for First Aid and Rehabilitation in Orthopaedic Trauma 2020Y2014Fuzhou Health Technology Project 2021-S-161
6 · The paper itself

Abstract

The optimal surgical approach and placement of plates for the treatment of distal third diaphyseal fracture of the humerus are the subjects of debate. The aim of this retrospective study was to evaluate the clinical and radiographic outcomes of modified medial minimally invasive plate osteosynthesis (MIPO) techniques using a double technique for the treatment of distal third diaphyseal fracture of the humerus. A total of 30 patients with a distal third diaphyseal fracture of the humerus were selected from our hospital. Patients were seen between January 2017 and October 2022. They were treated with a modified medial approach combined with MIPO using a double plate technique. Patient demographics, operation time, bleeding volume, union time, complications, the mean fracture length (FL) and distal cortical length (DCL), and the number of screws in the distal fragment were analyzed. The function of the shoulder and elbow was evaluated using Neer's assessment of the shoulder and Mayo's assessment of the elbow. The FL was 56.1 ± 7.2 mm and the DCL was 38.3 ± 5.3 mm. The mean operative time was 84.8 ± 13.4 min (range 60-110 min). The mean blood loss during surgical treatment was 46.5 ± 10.2 ml (range 30-60 ml). Bone healing was observed in all patients from 10 to 16 weeks (average 12.1 ± 1.7) postoperatively, and one case with poor surgical wound healing was recorded. All the patients had good function of both the shoulder and elbow. The maximum flexibility of the elbow ranged from 130° to 145° (average 138.1 ± 4.8°), with a maximum flexibility straightness ranging from 0° to 5° (average 2.2 ± 1.3°). The Mayo elbow joint function score was 80-100 (average 91.4 ± 5.0). The Neer shoulder joint function score ranged from 85 to 100 (average 92.5 ± 3.9). The modified medial approach was beneficial it did not cause any iatrogenic radial nerve or ulnar nerve injuries. The anterior and the medial side plates are fixed perpendicular to the distal humerus and provide excellent stability at the same time producing better shoulder and elbow joint function.

Indexed as

Humeral FracturesFracture Fixation, InternalHumansHumerusMinimally Invasive Surgical ProceduresRetrospective StudiesTreatment Outcome

Identifiers

PMID38062094
PMCPMC10703802

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.