Evidence map›Paper›PMID 38059673›Full record

ArticleJournal of applied clinical medical physics2024

Single isocenter HyperArc treatment of multiple intracranial metastases: Targeting accuracy.

Fang Li, Noor Mail, Maria Stefania diMayorca, Travis J McCaw, Cihat Ozhasoglu, Ronald Lalonde, Jina Chang, Mohammed Saiful Huq

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Off-iso Winston-Lutz test on seven linear accelerators.Journal of applied clinical medical physics · 2024
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Fang LiRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
Noor MailRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
Maria Stefania diMayorcaRadiation Oncology, Montefiore Medical Center, Bronx, New York, USA.
Travis J McCawRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
Cihat OzhasogluRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
Ronald LalondeRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
Jina ChangRadiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.ORCID https://orcid.org/0000-0003-0579-6020
Mohammed Saiful HuqRadiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
UPMC Hillman Cancer Center · USMontefiore Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PURPOSE/

objectives(A) To examine the alignment accuracy of CBCT guidance for brain metastases with off centered isocenters, (B) to test dose delivery and targeting accuracy for single isocenter treatments with multiple brain metastases. We report the results of the end-to-end test for Truebeam stereotactic radiosurgery (SRS). MATERIALS/

methodsAn anthropomorphic CT head phantom was drilled with five MOSFET inserts and two PTW Pinpoint chamber inserts. The phantom was simulated, planned, and delivered. For the purpose of comparing the accuracy of alignment, CBCTs were acquired with the isocenter centered and offset superiorly 8 cm, inferiorly 8 cm, anteriorly 7 cm, posteriorly 7 cm, and right 5 cm. There were six degrees of freedom corrections applied to the plans, as well as intentional rotational and translational errors for dose comparisons. Dose accuracy checks were performed with MOSFET and PTW Pinpoint chamber, and targeting accuracy was assessed with GafChromic films.

result(A) Compared to centered CBCT, off-centered CBCT scan showed some alignment errors, with a maximum difference of 0.6-degree pitch and 0.9 mm translation when the phantom was placed 8 cm inferior off center. (B) For the single isocenter plan, measured doses of the five MOSFET were 95%-100% of the planned dose, whereas the multiple isocenter plans were 96%-100%. With intentional setup errors of 1-degree pitch, doses were 97.1%-100.4% compared to the perfect setup. The same was found for the two pinpoint chamber readings with 1-degree rotation and 1 mm translation. (C) Targeting accuracy for targets at the isocenter is 0.67 mm, within the machine specification of 0.75 mm. Targeting accuracy for isocenters 6-12 cm away from the target is in the range 0.67-1.18 mm.

conclusion(A) Single isocenter HyperArc treatments for multiple brain metastases are feasible and targeting accuracy is clinically acceptable. (B) The vertex in a cranial scan is very important for proper alignment.

Indexed as

Brain NeoplasmsRadiosurgeryRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedHyperArcintracranial SRS/SBRT

Identifiers

PMID38059673
PMCPMC10795440
OpenAlexW4389452616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.