Evidence map›Paper›PMID 38054727›Full record

ArticleOperative neurosurgery (Hagerstown, Md.)2023

Robotic-Assisted Navigation for Stereotactic Neurosurgery: A Cadaveric Investigation of Accuracy, Time, and Radiation.

William Anderson, Francisco A Ponce, Michael J Kinsman, Sepehr Sani, Brian Hwang, Diana Ghinda, Michael Kogan, Jonathan M Mahoney, Dhara B Amin, Margaret Van Horn and 3 more

Open access · hybridAbstract read
In one paragraph

Article in Operative neurosurgery (Hagerstown, Md.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 7 institutions in 1 country.

William AndersonDepartment of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA.
Francisco A PonceDepartment of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
Michael J KinsmanNeurosurgery, University of Kansas Medical Center, Kansas City, Kansas, USA.
Sepehr SaniDepartment of Neurosurgery, Rush University Medical Center, Chicago, Illinois, USA.
Brian HwangDepartment of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA.
Diana GhindaDepartment of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA.
Michael KoganDepartment of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania, USA.
Jonathan M MahoneyMusculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA.
Dhara B AminMusculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA.
Margaret Van HornMusculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA.
Joshua P McGuckinMusculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA.ORCID 0000-0001-6426-4054
Dominic Razo-CastanedaSchool of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Brandon S BucklenMusculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA.
National Audubon Society · USJohns Hopkins Hospital · USBarrow Neurological Institute · USDrexel University · USRush University Medical Center · USThomas Jefferson University Hospital · USUniversity of Kansas Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesDespite frequent use, stereotactic head frames require manual coordinate calculations and manual frame settings that are associated with human error. This study examines freestanding robot-assisted navigation (RAN) as a means to reduce the drawbacks of traditional cranial stereotaxy and improve targeting accuracy.

methodsSeven cadaveric human torsos with heads were tested with 8 anatomic coordinates selected for lead placement mirrored in each hemisphere. Right and left hemispheres of the brain were randomly assigned to either the traditional stereotactic arc-based (ARC) group or the RAN group. Both target accuracy and trajectory accuracy were measured. Procedural time and the radiation required for registration were also measured.

resultsThe accuracy of the RAN group was significantly greater than that of the ARC group in both target (1.2 ± 0.5 mm vs 1.7 ± 1.2 mm, P = .005) and trajectory (0.9 ± 0.6 mm vs 1.3 ± 0.9 mm, P = .004) measurements. Total procedural time was also significantly faster for the RAN group than for the ARC group (44.6 ± 7.7 minutes vs 86.0 ± 12.5 minutes, P < .001). The RAN group had significantly reduced time per electrode placement (2.9 ± 0.9 minutes vs 5.8 ± 2.0 minutes, P < .001) and significantly reduced radiation during registration (1.9 ± 1.1 mGy vs 76.2 ± 5.0 mGy, P < .001) compared with the ARC group.

conclusionIn this cadaveric study, cranial leads were placed faster and with greater accuracy using RAN than those placed with conventional stereotactic arc-based technique. RAN also required significantly less radiation to register the specimen's coordinate system to the planned trajectories. Clinical testing should be performed to further investigate RAN for stereotactic cranial surgery.

Identifiers

PMID38054727
PMCPMC11008650
OpenAlexW4389381974

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.