Observational studyEuropean journal of pediatrics2024
Assessing the diagnostic accuracy of lung ultrasound in determining invasive ventilation needs in neonates on non-invasive ventilation: An observational study from a tertiary NICU in India.
Observational study in European journal of pediatrics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The predictive value of newborn and infant lung ultrasound score for mechanical ventilation needs: a systematic review and meta-analysis.Frontiers in pediatrics · 2025Pooled it
- Nasal high-frequency oscillatory ventilation as primary respiratory support in preterm infants with respiratory distress syndrome: current evidence and clinical implications.European journal of pediatrics · 2026Review
- ESICM-ESPNIC international expert consensus on quantitative lung ultrasound in intensive care.Intensive care medicine · 2025Article
- Breathe easy, baby, breathe. Lung ultrasound in neonatal critical care.Frontiers in pediatrics · 2025Review
- The practice of a modified bubble CPAP therapy in a rural Sierra Leone SCBU-A pilot study.Frontiers in pediatrics · 2025Article
- Article
- Diagnostic Accuracy of Lung Ultrasound in Neonatal Diseases: A Systematized Review.Journal of clinical medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Effective management of neonatal respiratory distress requires timely recognition of when to transition from non-invasive to invasive ventilation. Although the lung ultrasound score (LUS) is useful in evaluating disease severity and predicting the need for surfactants, its efficacy in identifying neonates requiring invasive ventilation has only been explored in a few studies. This study aims to assess the accuracy of LUS in determining the need for invasive ventilation in neonates on non-invasive ventilation (NIV) support. From July 2021 to June 2023, we conducted a prospective study on 192 consecutively admitted neonates with respiratory distress needing NIV within 24 h of birth at our NICU in Hyderabad, India. The primary objective was the diagnostic accuracy of LUS in determining the need for invasive ventilation within 72 h of initiating NIV. We calculated LUS using the scoring system of Brat et al. (JAMA Pediatr 169:e151797, [10]). Treating physicians' assessments of the need for invasive ventilation served as the reference standard for evaluating LUS effectiveness. Out of 192 studied neonates, 31 (16.1%) required invasive ventilation. The median LUS was 5 (IQR: 2-8) for those on NIV and 10 (IQR: 7-12) for those needing invasive ventilation. The LUS had a strong discriminative ability for invasive ventilation with an AUC (area under the curve) of 0.825 (CI: 0.75-0.86, p = 0.0001). An LUS > 7 had 77.4% sensitivity (95% CI: 58.9-90.8%), 75.1% specificity (95% CI: 67.8-81.7%), 37.5% positive predictive value (PPV) (95% CI: 30.15-45.5%), 94.5% negative predictive value (NPV) (95% CI: 89.9-97.1%), 3.1 positive likelihood ratio (PLR) (95% CI: 2.2-4.3), 0.3 negative likelihood ratio (NLR) (95% CI: 0.15-0.58), and 75.5% overall accuracy (95% CI: 68.8-81.4%) for identifying invasive ventilation needs. In contrast, SAS, with a cutoff point greater than 5, has an AUC of 0.67. It demonstrates 62.5% sensitivity, 61.9% specificity, 24.7% PPV, 89.2% NPV, and an overall diagnostic accuracy of 61.9%. The DeLong test confirms the significance of this difference (AUC difference: 0.142, p = 0.04), underscoring LUS's greater reliability for NIV failure. Conclusion: This study underscores the diagnostic accuracy of the LUS cutoff of > 7 in determining invasive ventilation needs during the initial 72 h of NIV. Importantly, while lower LUS values typically rule out the need for ventilation, higher values, though indicative, are not definitive. What is known? • The effectiveness of lung ultrasound in evaluating disease severity and the need for surfactants in neonates with respiratory distress is well established. However, traditional indicators for transitioning from non-invasive to invasive ventilation, like respiratory distress and oxygen levels, have limitations, underscoring the need for reliable, non-invasive assessment tools. What is new? • This study reveals that a LUS over 7 accurately discriminates between neonates requiring invasive ventilation and those who do not. Furthermore, the lung ultrasound score outperformed the Silverman Andersen score for NIV failure in our population.