Evidence map›Paper›PMID 38050556›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2023

Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture.

Natalia Christina Angsana, Firman Setya Wardhana, Supanji, Mohammad Eko Prayogo, Muhammad Bayu Sasongko

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Natalia Christina AngsanaDepartment of Ophthalmology, Faculty of Medicine, Public Health, and Nursing, Universitas Gadjah Mada - Sardjito Eye Center, Dr. Sardjito General Hospital, Yogyakarta, Indonesia.
Firman Setya WardhanaDepartment of Ophthalmology, Faculty of Medicine, Public Health, and Nursing, Universitas Gadjah Mada - Sardjito Eye Center, Dr. Sardjito General Hospital, Yogyakarta, Indonesia.
SupanjiDepartment of Ophthalmology, Faculty of Medicine, Public Health, and Nursing, Universitas Gadjah Mada - Sardjito Eye Center, Dr. Sardjito General Hospital, Yogyakarta, Indonesia.ORCID 0000-0001-6911-9382
Mohammad Eko PrayogoDepartment of Ophthalmology, Universitas Gadjah Mada Academic Hospital, Yogyakarta, Indonesia.
Muhammad Bayu SasongkoDepartment of Ophthalmology, Faculty of Medicine, Public Health, and Nursing, Universitas Gadjah Mada - Sardjito Eye Center, Dr. Sardjito General Hospital, Yogyakarta, Indonesia.ORCID 0000-0002-0366-8335
Universitas Gadjah Mada · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To present a modified technique of 4-point scleral fixation using polymethyl methacrylate (PMMA) 2 eyelets intraocular lens (IOL) with 8-0 polypropylene sutures. Methods: A 270-degree conjunctival peritomy is done, and 4 sclerotomies (2 nasal and 2 temporal) are created. Lamellar scleral or clear corneal incision is made at superior site (6 mm wide for sclera or 5.5-6 mm for corneal). A short segment of 8-0 polypropylene is inserted into each eyelet, each thread of the suture is externalized through the sclerotomy site, and the lens is inserted. The suture is tightened evenly, and the knot is rotated and internalized. Scleral incision and conjunctival peritomy are sutured with 8-0 vicryl. Results: We have performed this technique in 6 patients with excellent visual outcomes and no reported complications over 1 year of follow-up. This technique has practical advantages including rigid and stable PMMA IOL, high tensile, and slim 8-0 polypropylene suture which is easily internalized and less irritated, and affordable and widely available overall consumables. Conclusion: We present a modified 4-point scleral fixation technique for posterior chamber IOL placement using PMMA IOL with 2 eyelets and 8-0 polypropylene as compared to previous studies that used foldable IOL with 4 eyelets and 10-0 polypropylene or Gore-Tex sutures. This procedure has moderate technical complexity, comparable to previously reported techniques with good overall clinical outcomes and several practical advantages, particularly related to the affordability and availability of the consumables.

Indexed as

2-eyeletsfour-pointpolymethyl methacrylatesecondary intraocular lens implantationsutured scleral fixation

Identifiers

PMID38050556
PMCPMC10693757
OpenAlexW4389145978

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.