ArticleArthroplasty (London, England)2023
CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice.
Article in Arthroplasty (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 citations in OpenAlex.
- Imageless navigation demonstrates limited anteversion agreement with postoperative EOS assessment in lateral decubitus total hip arthroplasty.Journal of robotic surgery · 2026Trial
- Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary.Archives of orthopaedic and trauma surgery · 2026Trial
- Asia-Pacific expert consensus on robotic-assisted hip and knee arthroplasty.Arthroplasty (London, England) · 2026Review
- Accuracy of two different imageless navigation systems for leg length and global offset change in total hip arthroplasty: A comparison using two-dimensional radiographic and three-dimensional CT-based evaluation.International orthopaedics · 2026Article
- A registration method for total hip arthroplasty navigation system based on point cloud alignment.Frontiers in medical technology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe aim of this study was to report on the validity of the Naviswiss handheld image-free navigation device for accurate intraoperative measurement of THA component positioning, in comparison with the three-dimensional (3D) reconstruction of computed tomography (CT) images as the gold standard.
methodsA series of patients presenting to a single-surgeon clinic with end-stage hip osteoarthritis received primary hip arthroplasty with the anterolateral muscle-sparing surgical approach in the supine position. Imageless navigation was applied during the procedure with bone-mounted trackers applied to the greater trochanter and ASIS. Patients underwent routine CT scans before and after surgery and these were analyzed by using three-dimensional reconstruction to generate cup orientation, offset and leg length changes, which were compared to the intraoperative measurements provided by the navigation system. Estimates of agreement between the intraoperative and image-derived measurements were assessed with and without correction for bias and declared cases with potential measurement issues.
resultsThe mean difference between intraoperative and postoperative CT measurements was within 2° for angular measurements and 2 mm for leg length. Absolute differences for the two indices were between 5° and 4 mm. Mean bias was 1.9°-3.6° underestimation for cup orientation and up to 2 mm overestimation for leg length change, but absolute thresholds of 10° and 10 mm were not exceeded by 95% limits of agreement (LOA), especially after correction for bias. Four cases (12%) were declared intraoperatively for issues with fixation on the greater trochanter. Inclusion of these cases generated acceptable accuracy overall and their omission failed to improve between-case variability in accuracy or LOA for both offset and leg length.
conclusionsThe accuracy of the Naviswiss system applied during primary THA in a supine position and anterolateral surgical approach falls within clinically acceptable recommendations for acetabular cup placement, femoral offset, and length. With refinements to surgical technique to adapt to the navigation hardware, the system could be further improved with regression-based bias correction.
trial registrationRegistered with the Australian New Zealand Clinical Trials Registry (ACTRN12618000317291).