Evidence map›Paper›PMID 38049615›Full record

ArticleEuropean radiology experimental2023

Evaluation of MR-safe bioptomes for MR-guided endomyocardial biopsy in minipigs: a potential radiation-free clinical approach.

Angelika Svetlove, Christian O Ritter, Christian Dullin, Michael Schmid, Senta Schauer, Johannes Uihlein, Martin Uecker, Matthias Mietsch, Christine Stadelmann, Joachim Lotz and 1 more

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 2 countries.

Angelika SvetloveTranslational Molecular Imaging, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Christian O RitterInstitute for Diagnostic and Interventional Radiology, University Medical Centre, Göttingen, Germany.
Christian DullinTranslational Molecular Imaging, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Michael SchmidEPflex Feinwerktechnik GmbH, Dettingen an der Erms, Germany.
Senta SchauerEPflex Feinwerktechnik GmbH, Dettingen an der Erms, Germany.
Johannes UihleinEPflex Feinwerktechnik GmbH, Dettingen an der Erms, Germany.
Martin UeckerInstitute for Diagnostic and Interventional Radiology, University Medical Centre, Göttingen, Germany.
Matthias MietschDZHK (German Centre for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany.
Christine StadelmannDepartment of Neuropathology, University Medical Centre, Göttingen, Germany.
Joachim LotzInstitute for Diagnostic and Interventional Radiology, University Medical Centre, Göttingen, Germany.
Christina Unterberg-BuchwaldInstitute for Diagnostic and Interventional Radiology, University Medical Centre, Göttingen, Germany. unterberg@med.uni-goettingen.de.
Universitätsmedizin Göttingen · DEUniversity of Göttingen · DEGerman Primate Center · DEKlinikum St. Marien Amberg · DEMax Planck Institute for Multidisciplinary Sciences

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDiagnostic accuracy of endomyocardial biopsy could improve if clinically safe magnetic resonance (MR)-compatible bioptomes were available. We explored two novel MR-compatible cardiac bioptomes for performance, safety, and clinical viability, employing in vivo minipig trials and phase-contrast synchrotron radiation computed microtomography (SRµCT).

methodsAnalysis of ex vivo obtained pig endomyocardial biopsies was performed using phase-contrast SRµCT and conventional two-dimensional histology. The technical performance was evaluated by measuring volume, inner and outer integrities, compression, and histological diagnostic value in 3 sets (6 per set) of biopsies for each experimental bioptome. The bioptomes were tested in vivo in 3 healthy minipigs per bioptome. The clinical feasibility was evaluated by procedural and cutting success as well as histological diagnostic value.

resultsThe bioptome with the 'grind-grind' design achieved similar values to control in compression (p = 0.822), inner (p = 0.628), and outer (p = 0.507), integrities ex vivo. It showed a better performance in the in vivo real-time MRI setting demonstrating a higher cutting success (91.7%) than the 'grind-anvil' (86.2%) design. In both ex vivo and in vivo evaluations, the 'grind-grind' design displayed sufficient diagnostic value (83% and 95%). The 'grind-anvil' design showed adequate diagnostic value both ex vivo and in vivo (78% and 87.5%) but was not comparable to control according to the three-dimensional (3D) analysis.

conclusionA novel MR-compatible bioptome was identified as plausible in a clinical setting. Additionally, SRµCT and subsequent 3D structural analysis could be valuable in the label-free investigation of myocardial tissue at a micrometer level. RELEVANCE STATEMENT: Implementation of MR-guided biopsy can improve animal studies on structural myocardial changes at any point in an experimental setup. With further improvements in guiding catheters, MR-guided biopsy, using the new bioptome, has a potential to increase quality and diagnostic accuracy in patients both with structural and inflammatory cardiomyopathies. KEY POINTS: • Novel MR-compatible bioptomes show promise for a clinical application. • SRµCT enabled detailed analysis of endomyocardial biopsies. • The bioptomes showed adequate in vivo performance without major complications.

Indexed as

HeartMagnetic Resonance ImagingAnimalsBiopsyHumansMagnetic Resonance SpectroscopySwineSwine, MiniatureBiopsyMagnetic resonance imaging (interventional)SynchrotronsX-ray microtomography

Identifiers

PMID38049615
PMCPMC10695907
OpenAlexW4389323380

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked