FLEX: FLexible Transducer With External Tracking for Ultrasound Imaging With Patient-Specific Geometry Estimation.

Debarghya China, Ziwei Feng, Hamed Hooshangnejad, Daniel Sforza, Prasad Vagdargi, Muyinatu A Lediju Bell, Ali Uneri, Alejandro Sisniega, Kai Ding

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Debarghya China
Ziwei Feng
Hamed Hooshangnejad
Daniel Sforza
Prasad Vagdargi
Muyinatu A Lediju Bell
Ali Uneri
Alejandro Sisniega
Kai Ding

Funding

Training In Orthopaedic Team ScienceT32AR067708 · NIAMS · JOHNS HOPKINS UNIVERSITY · PI JONES, LYNNE C., SHAFIQ, BABAR · 2015 to 2024
$2.0M
Spacer Enabled Robust Radiation Therapy (SERRT)R37CA229417 · NCI · JOHNS HOPKINS UNIVERSITY · PI DING, KAI · 2018 to 2021
$1.5M
NCI NIH HHS R37 CA229417NIAMS NIH HHS T32 AR067708
6 · The paper itself

Abstract

Flexible array transducers can adapt to patient-specific geometries during real-time ultrasound (US) image-guided therapy monitoring. This makes the system radiation-free and less user-dependency. Precise estimation of the flexible transducer's geometry is crucial for the delay-and-sum (DAS) beamforming algorithm to reconstruct B-mode US images. The primary innovation of this research is to build a system named FLexible transducer with EXternal tracking (FLEX) to estimate the position of each element of the flexible transducer and reconstruct precise US images. FLEX utilizes customized optical markers and a tracker to monitor the probe's geometry, employing a polygon fitting algorithm to estimate the position and azimuth angle of each transducer element. Subsequently, the traditional DAS algorithm processes the delay estimation from the tracked element position, reconstructing US images from radio-frequency (RF) channel data. The proposed method underwent evaluation on phantoms and cadaveric specimens, demonstrating its clinical feasibility. Deviations in tracked probe geometry compared to ground truth were minimal, measuring 0.50 ± 0.29 mm for the CIRS phantom, 0.54 ± 0.35 mm for the deformable phantom, and 0.36 ± 0.24 mm on the cadaveric specimen. Reconstructing the US image using tracked probe geometry significantly outperformed the untracked geometry, as indicated by a Dice score of 95.1 ± 3.3% versus 62.3 ± 9.2% for the CIRS phantom. The proposed method achieved high accuracy (<0.5 mm error) in tracking the element position for various random curvatures applicable for clinical deployment. The evaluation results show that the radiation-free proposed method can effectively reconstruct US images and assist in monitoring image-guided therapy with minimal user dependency.

Indexed as

AlgorithmsTransducersCadaverHumansPhantoms, ImagingUltrasonography

Identifiers

PMID38048239
PMCPMC10998498

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.