Evidence map›Paper›PMID 38046967›Full record

ArticleIndian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India

Near-lossless Compression of Tc-99 m DMSA Scan Images Using Discrete Cosine Transformation.

Priya Yadav, Anil Kumar Pandey, Jagrati Chaudhary, Param Dev Sharma, Jasim Jaleel, Vivek Baghel, Chetan Patel, Rakesh Kumar

Abstract read
In one paragraph

Article in Indian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Priya YadavDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Anil Kumar PandeyDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Jagrati ChaudharyDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Param Dev SharmaDepartment of Computer Science, SGTB Khalsa College, University of Delhi, New Delhi, India.
Jasim JaleelDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Vivek BaghelDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Chetan PatelDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Rakesh KumarDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim and Objective: The objective of this study was to optimize the threshold for discrete cosine transform (DCT) coefficients for near-lossless compression of Tc-99 m Dimercaptosuccinic acid (DMSA) scan images using discrete cosine transformation. Materials and Methods: Two nuclear medicine (NM) Physicians after reviewing several Tc-99 m DMSA scan images provided 242 Tc-99 m DMSA scan images that had scar. These Digital imaging and communication in medicine (DICOM) images were converted in the Portable Network Graphics (PNG) format. DCT was applied on these PNG images, which resulted in DCT coefficients corresponding to each pixel of the image. Four different thresholds equal to 5, 10, 15, and 20 were applied and then inverse discrete cosine transformation was applied to get the compressed Tc-99 m DMSA scan images. Compression factor was calculated as the ratio of the number of nonzero elements after thresholding DCT coefficients to the number of nonzero elements before thresholding DCT coefficients. Two NM physicians who had provided the input images visually compared the compressed images with its input image, and categorized the compressed images as either acceptable or unacceptable. The quality of compressed images was also assessed objectively using the following eight image quality metrics: perception-based image quality evaluator, structural similarity index measure (SSIM), multiSSIM, feature similarity indexing method, blur, global contrast factor, contrast per pixel, and brightness. Pairwise Wilcoxon signed-rank sum tests were applied to find the statistically significant difference between the value of image quality metrics of the compressed images obtained at different thresholds and the value of the image quality metrics of its input images at the level of significance = 0.05. Results: At threshold 5, (1) all compressed images (242 out of 242 Tc-99 m DMSA scan images) were acceptable to both the NM Physicians, (2) Compressed image looks identical to its original image and no loss of clinical details was noticed in compressed images, (3) Up to 96.65% compression (average compression: 82.92%) was observed, and (4) Result of objective assessment supported the visual assessment. The quality of compressed images at thresholds 10, 15, and 20 was significantly better than that of input images at Conclusions: Up to 96.65%, near-losses compression of Tc-99 m DMSA images was found using DCT by thresholding DCT coefficients at a threshold value equal to 5.

Indexed as

Discrete cosine transformimage compressionTc-99 m DMSA scan images

Identifiers

PMID38046967
PMCPMC10693356

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.