Evidence map›Paper›PMID 38046510›Full record

ArticleBioinformation2023

Analysis of biochemical analytes using six sigma metrics with two analyzers at an Indian lab setting.

Ranjeeta Gadde, Venkatappa Hm

Abstract read
In one paragraph

Article in Bioinformation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ranjeeta GaddeKanva Diagnostic Services Private Ltd, #744, 11th Block, 2nd Stage, Marilingappa Extension, Nagarbhavi, Bengaluru - 560072, Karnataka, India.
Venkatappa HmKanva Diagnostic Services Private Ltd, #744, 11th Block, 2nd Stage, Marilingappa Extension, Nagarbhavi, Bengaluru - 560072, Karnataka, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A zero defects goal was implemented in the clinical laboratory settings using a six-sigma model. Daily Internal Quality Control (IQC) and external quality control data from April-September 2023 was extracted to calculate the sigma metrics of 21 biochemical analytes based on Total Error Allowable (TEa), % bias and co-efficient of variation percent (CV%). A retrospective comparative study was conducted in the department of Clinical Biochemistry at Kanva Diagnostic Services Pvt. Ltd, Bengaluru, India. The analytical performance of the 21 biochemical analytes was tested on Cobas 6000 and C311 analyzers. Quality Goal Index (QGI) and root cause analysis was calculated to infer the reason for the deviation of six sigma. Method decision charts were plotted to show the comparison of the problem analytes on both the analyzers. On Cobas 6000 at level 1 IQC, out of 21 analytes, 10 analytes showed σ>6 and 10 analytes showed σ 3-6 and on C311, 15 analytes which showed σ>6 and 6 analytes that showed σ 3-6. On Cobas 6000 at level 2 IQC, out of 21 analytes, 12 analytes showed σ>6 and 8 analytes showed σ 3-6 and on C311 17 analytes showed σ>6 and 4 analytes showed σ 3-6. Creatinine failed to meet minimal sigma performance at both levels of IQC on Cobas 6000.

Indexed as

quality goal indexsigma metricWestgard rules

Identifiers

PMID38046510
PMCPMC10692979

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.