ArticleJournal of orthopaedics2024
Comparison of three-versus two-dimensional pre-operative planning for total hip arthroplasty.
Article in Journal of orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Proximal femoral morphometry and its association with hip fracture patterns: a systematic review with meta-analysis.Surgical and radiologic anatomy : SRA · 2026Pooled it
- Three-dimensional and artificial intelligence-assisted preoperative templating in total hip arthroplasty: a systematic review and meta-analysis.Arthroplasty (London, England) · 2026Review
- Two-Dimensional Preoperative Digital Templating is Less Accurate When Using a Collared Triple Taper Stem Versus a Single Taper Design.Arthroplasty today · 2025Article
- Planning Accuracy and Stem Offset Assessment in Digital Two-Dimensional Versus Three-Dimensional Planning in Cementless Hip Arthroplasty: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2024Review
- Novel Surgical Technique for Total Knee Arthroplasty Integrating Kinematic Alignment and Real-Time Elongation of the Ligaments Using the NextAR System.Journal of personalized medicine · 2024Article
- [Estimation of acetabular cup prosthesis coverage rate in total hip arthroplasty based on X-ray films].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- To further incorporate computer-aided designs to improve preoperative planning in total hip arthroplasty: a cohort study.Frontiers in surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: A successful clinical outcome for total hip arthroplasty (THA) depends on accurate sizing and positioning of the implants. Using three-dimensional (3-D) pre-operative planning with a computerized tomography (CT) scan has many potential advantages over conventional 2-D planning using radiographs, including potentially more accurate assessments of the size and anteversion of the acetabulum, as well as lateral femoral offset. The purpose of this study was to compare the accuracy of 3-D to 2-D templating with respect to acetabular and femoral size, as well as lateral femoral offset. Methods: Pre-operative templating data was collected prospectively from a consecutive series of 290 primary THAs (acetabulum on all, femoral component on 255 of the cases using one specific stem). All cases were initially templated on a digital imaging picture archiving and communication (PACS) system with calibrated images to estimate the acetabular size, femoral size, and lateral femoral offset. The 3-D templating was then performed with software based on a CT scan, and the results were compared to what was surgically implanted. Results: The 3-D templating for the acetabulum was accurate 99.7% of the time based on the final implanted component. The 2-D templating for the acetabulum was accurate 39% of the time, with 46% of cases templating smaller and 15% templating larger. The 3-D templating of the femoral component was accurate 63% of the time, and within one size of final implant in 96% of cases. The 2-D templating of the femoral component was accurate 53% of the time and within one size of final implant in 94% of cases. The 2-D templated femoral offset was accurate 87% of the time and was changed in 13% of cases after 3-D templating. Conclusion: The CT-based 3-D preoperative planning was superior to 2-D planning for THA with respect to acetabular size, femoral size, and lateral femoral offset. Precise acetabular component sizing conserves bone and allows for a more predictable press fit, while facilitating efficient inventory management. Lateral femoral offset is often difficult to measure on 2-D images, and 3-D templating consistently allows for accurate offset restoration, which is important for normal hip function and stability.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.