Evidence map›Paper›PMID 38046446›Full record

ArticleMedical research archives2023

An Echogenic Clot Method for Thrombolysis Monitoring in Thrombotic Stroke Models.

Dalton E Carter, Tao Peng, Melanie R Moody, Shao-Ling Huang, David D McPherson, Melvin E Klegerman

Open access · diamondAbstract read
In one paragraph

Article in Medical research archives, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Dalton E CarterDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
Tao PengDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
Melanie R MoodyDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
Shao-Ling HuangDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
David D McPhersonDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
Melvin E KlegermanDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 77030, U.S.A.
The University of Texas Health Science Center at Houston · US

Funding

Ultrasound-Assisted Thrombolysis for Stroke TherapyR01NS047603 · NINDS · UNIVERSITY OF CINCINNATI · PI HOLLAND, CHRISTY K. · 2004 to 2018
$7.5M
Echogenic Targeted Liposomes: Transfection/Drug DeliveryR01HL135092 · NHLBI · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI David D McPherson · 2017 to 2026
$5.0M
NHLBI NIH HHS R01 HL135092NINDS NIH HHS R01 NS047603
6 · The paper itself

Abstract

To demonstrate thrombolytic efficacy of a tissue plasminogen activator (tPA)-loaded echogenic liposome (TELIP) formulation in a rabbit thrombotic stroke model (the most relevant animal model for evaluation of directed thrombolytic therapy for ischemic stroke), we sought to develop a means of monitoring thrombus dissolution quantitatively by ultrasound imaging methods. We hypothesized that a gas-free ultrasound contrast agent can be incorporated into blood clots at a concentration that does not affect the tPA-mediated clot dissolution rate, while enabling quantitative assessment of the clot dissolution rate. Clots were formed from a mixture of whole rabbit blood, 1 M calcium chloride, human thrombin and varying amounts of microcrystalline cellulose. Washed clots in tubes were weighed at 30, 60 and 90 minutes after addition of recombinant tPA (rtPA) in porcine plasma (100 μg/ml). Clot echogenicity at each time point was assessed using a Philips HDI 5000 ultrasound system using an L12-5 linear array probe. Recorded Images underwent videodensitometric analysis that converted image reflectivity to mean gray scale values (MGSV). We found that 1.12 mg/ml of microcrystalline cellulose in rabbit blood clots (0.2 ml) provided optimal echogenicity without affecting clot dissolution rates (0.3-0.6 mg/min.) caused by rtPA. The clot dissolution rate measured by videodensitometric analysis of the echogenic clots agreed well with that determined by mass loss measurements (0.28% 0-time value/minute). This method will be important for demonstrating

Identifiers

PMID38046446
PMCPMC10691855
OpenAlexW4362480346

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.