ArticleACS omega2023
Development and Validation of RP-HPLC Method for the Determination of Enoxaparin Sodium in Dry Injection Formulation.
Article in ACS omega, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development and Validation of RP-HPLC Method forACS omega · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Enoxaparin sodium is an anticoagulant medication that is used as a blood thinning agent. It is mostly used for the treatment and prevention of deep vein thrombosis (DVT) and pulmonary embolism (PE). It is also used in certain surgeries and during pregnancy. For the treatment of acute coronary syndrome (ACS) and heart attacks, it may be used. Enoxaparin sodium was validated by the RP-HPLC method. A simple RP-HPLC method was developed in a single HPLC run in a dry powder injection formulation. All injections of HPLC sample were 20 μL volume. The chromatographic separation was completed in the isocratic mode. The used column was USP-L8 (250 mm × 4.6 mm) of BDS type of 10 μm meters in the same mobile phase throughout the analysis by using methanol and ultrapure water with a ratio of 7:93, respectively. The flow rate was 1.0 mL/min. The mobile phase was filtered through 0.45 μm filter paper, and isocratic elution was performed. The refractive index (RI) detector was used to analyze this sample. The specific peak of enoxaparin sodium was observed at 5:56 min. The calculated detection limit (LOD) was 0.351 ppm, and the calculated quantitation limit was 1.063 ppm. In repeatability of precision, the average calculated assay (%) was 100.85%, and the calculated RSD (%) was 0.01. In the accuracy test, the RSD (%) was 0.50, and the mean recovery (%) was 100.35. The system's suitability was within the limit. This newly developed method is proposed according to ICH guidelines, and rules and can be applied effectively for the exact estimation of enoxaparin sodium in injection formulation. This newly developed methodology is affordable in cost as long as less time is taken and the consumption of samples is in smaller quantities for every investigation. In medicinal chemistry, the USP (United States Pharmacopeia) and BP (British Pharmacopeia) are directly involved in production as well as in quality testing.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.