Evidence map›Paper›PMID 38041135›Full record

ArticleJournal of neuroengineering and rehabilitation2023

Mixed methods usability evaluation of an assistive wearable robotic hand orthosis for people with spinal cord injury.

Jan Dittli, Jan T Meyer, Jessica Gantenbein, Tobias Bützer, Raffaele Ranzani, Anita Linke, Armin Curt, Roger Gassert, Olivier Lambercy

Open access · goldAbstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 19 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Jan Dittli *Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland. relab.publications@hest.ethz.ch.
Jan T Meyer *Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
Jessica Gantenbein *Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
Tobias BützerRehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
Raffaele RanzaniRehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
Anita LinkeSpinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland.
Armin CurtSpinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland.
Roger GassertRehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
Olivier LambercyRehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Lengghalde 5, 8008, Zurich, Switzerland.
ETH Zurich · CHUniversitätsklinik Balgrist · CH

Funding

NCCR Robotics 51NF40_185543
6 · The paper itself

Abstract

backgroundRobotic hand orthoses (RHO) aim to provide grasp assistance for people with sensorimotor hand impairment during daily tasks. Many of such devices have been shown to bring a functional benefit to the user. However, assessing functional benefit is not sufficient to evaluate the usability of such technologies for daily life application. A comprehensive and structured evaluation of device usability not only focusing on effectiveness but also efficiency and satisfaction is required, yet often falls short in existing literature. Mixed methods evaluations, i.e., assessing a combination of quantitative and qualitative measures, allow to obtain a more holistic picture of all relevant aspects of device usability. Considering these aspects already in early development stages allows to identify design issues and generate generalizable benchmarks for future developments.

methodsWe evaluated the short-term usability of the RELab tenoexo, a RHO for hand function assistance, in 15 users with tetraplegia after a spinal cord injury through a comprehensive mixed methods approach. We collected quantitative data using the Action Research Arm Test (ARAT), the System Usability Scale (SUS), and timed tasks such as the donning process. In addition, qualitative data were collected through semi-structured interviews and user observations, and analyzed with a thematic analysis to enhance the usability evaluation. All insights were attributed and discussed in relation to specifically defined usability attributes such as comfort, ease of use, functional benefit, and safety.

resultsThe RELab tenoexo provided an immediate functional benefit to the users, resulting in a mean improvement of the ARAT score by 5.8 points and peaking at 15 points improvement for one user (clinically important difference: 5.7 points). The mean SUS rating of 60.6 represents an adequate usability, however, indicating that especially the RHO donning (average task time = 295 s) was perceived as too long and cumbersome. The participants were generally very satisfied with the ergonomics (size, dimensions, fit) of the RHO. Enhancing the ease of use, specifically in donning, increasing the provided grasping force, as well as the availability of tailoring options and customization were identified as main improvement areas to promote RHO usability.

conclusionThe short-term usability of the RELab tenoexo was thoroughly evaluated with a mixed methods approach, which generated valuable data to improve the RHO in future iterations. In addition, learnings that might be transferable to the evaluation and design of other RHO were generated, which have the potential to increase the daily life applicability and acceptance of similar technologies.

Indexed as

RoboticsRobotic Surgical ProceduresSpinal Cord InjuriesWearable Electronic DevicesHumansOrthotic DevicesMixed methodsRobotic hand orthosisUsabilityWearable robots

Identifiers

PMID38041135
PMCPMC10693050
OpenAlexW4389223369

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.