ArticleIUCrJ2024
STEM SerialED: achieving high-resolution data for ab initio structure determination of beam-sensitive nanocrystalline materials.
Article in IUCrJ, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 21 citations in OpenAlex.
- Tracking the redox reaction of the iron enzyme ribonucleotide reductase using continuous SerialED and SFX.Structure (London, England : 1993) · 2026Article
- Automated serial electron diffraction: implementation inJournal of applied crystallography · 2026Article
- Article
- Automated and real-time structure solution using 3D electron diffraction.Journal of applied crystallography · 2025Article
- Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Machine learning for the classification of serial electron diffraction patterns: synthetic data.Acta crystallographica. Section A, Foundations and advances · 2025Article
- On the use of beam precession for serial electron crystallography.Journal of applied crystallography · 2025Article
- 3D Electron Diffraction on Nanoparticles: Minimal Size and Associated Dynamical Effects.ACS nano · 2025Article
- Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination.IUCrJ · 2025Article
- Fast event-based electron counting for small-molecule structure determination by MicroED.Acta crystallographica. Section C, Structural chemistry · 2025Article
- Unit-cell parameters determination from a set of independent electron diffraction zonal patterns.Acta crystallographica. Section A, Foundations and advances · 2025Article
- Article
- Applying 3D ED/MicroED workflows toward the next frontiers.Acta crystallographica. Section C, Structural chemistry · 2024Article
- Poetry in motion: catching molecules in action.IUCrJ · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 3 countries.
Funding
Abstract
Serial electron diffraction (SerialED), which applies a snapshot data acquisition strategy for each crystal, was introduced to tackle the problem of radiation damage in the structure determination of beam-sensitive materials by three-dimensional electron diffraction (3DED). The snapshot data acquisition in SerialED can be realized using both transmission and scanning transmission electron microscopes (TEM/STEM). However, the current SerialED workflow based on STEM setups requires special external devices and software, which limits broader adoption. Here, we present a simplified experimental implementation of STEM-based SerialED on Thermo Fisher Scientific STEMs using common proprietary software interfaced through Python scripts to automate data collection. Specifically, we utilize TEM Imaging and Analysis (TIA) scripting and TEM scripting to access the STEM functionalities of the microscope, and DigitalMicrograph scripting to control the camera for snapshot data acquisition. Data analysis adapts the existing workflow using the software CrystFEL, which was developed for serial X-ray crystallography. Our workflow for STEM SerialED can be used on any Gatan or Thermo Fisher Scientific camera. We apply this workflow to collect high-resolution STEM SerialED data from two aluminosilicate zeolites, zeolite Y and ZSM-25. We demonstrate, for the first time, ab initio structure determination through direct methods using STEM SerialED data. Zeolite Y is relatively stable under the electron beam, and STEM SerialED data extend to 0.60 Å. We show that the structural model obtained using STEM SerialED data merged from 358 crystals is nearly identical to that using continuous rotation electron diffraction data from one crystal. This demonstrates that accurate structures can be obtained from STEM SerialED. Zeolite ZSM-25 is very beam-sensitive and has a complex structure. We show that STEM SerialED greatly improves the data resolution of ZSM-25, compared with serial rotation electron diffraction (SerialRED), from 1.50 to 0.90 Å. This allows, for the first time, the use of standard phasing methods, such as direct methods, for the ab initio structure determination of ZSM-25.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.