Evidence map›Paper›PMID 38036038›Full record

Observational studyJornal de pediatria

Comparison of the effectiveness of different high-flow devices in neonatal care.

Diogo Machado Kaminski, Graziela Ferreira Biazus, Rita C Silveira, Renato Soibelmann Procianoy

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Jornal de pediatria. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 58% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Diogo Machado KaminskiHospital de Clínicas de Porto Alegre, Department of Physiotherapy, Neonatology Service, Porto Alegre, RS, Brazil. Electronic address: dkaminski@hcpa.edu.br.
Graziela Ferreira BiazusHospital de Clínicas de Porto Alegre, Department of Physiotherapy, Neonatology Service, Porto Alegre, RS, Brazil.
Rita C SilveiraNewborn Section at Universidade Federal do Rio Grande do Sul, Hospital de Clínicas de Porto Alegre, Neonatology Service, Porto Alegre, RS, Brazil.
Renato Soibelmann ProcianoyNewborn Section at Universidade Federal do Rio Grande do Sul, Hospital de Clínicas de Porto Alegre, Neonatology Service, Porto Alegre, RS, Brazil.
Hospital de Clínicas de Porto Alegre · BRUniversidade Federal do Rio Grande do Sul · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the success rate of high-flow nasal cannula (HFNC) therapy using an adapted obsolete mechanical ventilator (MV), Optiflow™ and Vapotherm™ in newborns (NBs).

methodThis was a retrospective observational study conducted in the neonatal intensive care unit (NICU). The sample comprised NBs who underwent HFNC therapy due to ventilatory dysfunction, for weaning from non-invasive ventilation (NIV), or post-extubation. The three groups, stratified according to gestational age (GA) and birth weight, and corrected GA and weight at the beginning of HFNC use, were as follows: Optiflow ™, Vapotherm ™, and obsolete Mechanical Ventilator (MV) adapted for high flow therapy. Subsequently, the NBs were divided into a success group (SG) and a failure group (FG). HFNC success was defined as a therapy duration exceeding 72 h.

resultsA total of 209 NBs were evaluated, with 31.1 % using HFNC due to ventilatory dysfunction, 2.4 % after extubation, and 66.5 % after NIV weaning. HFNC success rate was observed in 90.9 % of the NBs, with no difference between equipment types (Vapotherm ™, Optiflow ™, and adapted VM).

conclusionDifferent types of HFNC equipment are equally effective when used in neonatology for respiratory dysfunction, as a method of weaning from NIV and post-extubation. Adapted obsolete MV can be an alternative for HFCN therapy in resource-constrained settings.

Indexed as

Noninvasive VentilationRespiratory InsufficiencyBirth WeightCannulaHumansInfant, NewbornOxygen Inhalation TherapyRespiration, ArtificialRetrospective StudiesExtubationHigh-flow nasal cannulaNewbornNon-invasive ventilationPretermRespiratory distress

Identifiers

PMID38036038
PMCPMC10943304
OpenAlexW4389047913

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.