Evidence map›Paper›PMID 38034822›Full record

ArticleFrontiers in pediatrics2023

Measurement of MMP-7 in micro-volume peripheral blood: development of dried blood spot approach.

Jingying Jiang, Shuyang Liu, Min Du, Jiale Deng, Gong Chen, Yifan Yang, Rui Dong, Zhuo Fang, Shan Zheng

Open access · goldAbstract read
In one paragraph

Article in Frontiers in pediatrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Jingying Jiang *Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Shuyang Liu *Department of Data & Analytics, WuXi Diagnostics Innovation Research Institute, Shanghai, China.
Min Du *Department of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Jiale DengDepartment of Data & Analytics, WuXi Diagnostics Innovation Research Institute, Shanghai, China.
Gong ChenDepartment of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Yifan YangDepartment of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Rui DongDepartment of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Zhuo FangDepartment of Data & Analytics, WuXi Diagnostics Innovation Research Institute, Shanghai, China.
Shan ZhengDepartment of Pediatric Surgery, Shanghai Key Laboratory of Birth Defect, and Key Laboratory of Neonatal Disease, Ministry of Health, Children's Hospital of Fudan University, Shanghai, China.
Children's Hospital of Fudan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Serum matrix metalloproteinase-7 (MMP-7) is significant in differentiating biliary atresia (BA). This study aims to develop a new peripheral blood quantitative collection device to detect MMP-7 levels via dried blood spot (DBS). Methods: This is a diagnostic accuracy test. Serum and DBS MMP-7 concentrations were measured using an ELISA kit. Intraoperative cholangiography and subsequent histological examinations were used to confirm BA diagnoses. Results: A total of 241 infants with obstructive jaundice were enrolled, among whom 168 were BA. Linear regression showed DBS MMP-7 correlated well with serum MMP-7 ( Conclusions: Serum and DBS MMP-7 correlate well, both of which have high accuracy in the diagnosis of BA, while the requirements for the storage of DBS are low.

Indexed as

biliary atresiadiagnosisdried blood spotMMP-7screening

Identifiers

PMID38034822
PMCPMC10684727
OpenAlexW4388705021

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.