Evidence map›Paper›PMID 38034476›Full record

ArticleBeilstein journal of nanotechnology2023

A multi-resistance wide-range calibration sample for conductive probe atomic force microscopy measurements.

François Piquemal, Khaled Kaja, Pascal Chrétien, José Morán-Meza, Frédéric Houzé, Christian Ulysse, Abdelmounaim Harouri

Abstract read
In one paragraph

Article in Beilstein journal of nanotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Advanced atomic force microscopy techniques V.Beilstein journal of nanotechnology · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

François PiquemalLaboratoire national de métrologie et d'essais - LNE, Trappes, 78197 Cedex, France.ORCID https://orcid.org/0000-0002-7950-0475
Khaled KajaLaboratoire national de métrologie et d'essais - LNE, Trappes, 78197 Cedex, France.ORCID https://orcid.org/0000-0002-2394-4595
Pascal ChrétienUniversité Paris-Saclay, CentraleSupélec, CNRS, Laboratoire de Génie Électrique et Électronique de Paris, 91192, Gif-sur-Yvette, France.ORCID https://orcid.org/0009-0005-5177-1360
José Morán-MezaLaboratoire national de métrologie et d'essais - LNE, Trappes, 78197 Cedex, France.ORCID https://orcid.org/0000-0001-6352-6040
Frédéric HouzéUniversité Paris-Saclay, CentraleSupélec, CNRS, Laboratoire de Génie Électrique et Électronique de Paris, 91192, Gif-sur-Yvette, France.ORCID https://orcid.org/0000-0001-8054-3184
Christian UlysseCentre de Nanosciences et de Nanotechnologies - C2N, Université Paris-Saclay, CNRS, UMR 9001, Palaiseau, 91120, France.ORCID https://orcid.org/0000-0001-9814-0535
Abdelmounaim HarouriCentre de Nanosciences et de Nanotechnologies - C2N, Université Paris-Saclay, CNRS, UMR 9001, Palaiseau, 91120, France.ORCID https://orcid.org/0000-0003-1813-6347

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measuring resistances at the nanoscale has attracted recent attention for developing microelectronic components, memory devices, molecular electronics, and two-dimensional materials. Despite the decisive contribution of scanning probe microscopy in imaging resistance and current variations, measurements have remained restricted to qualitative comparisons. Reference resistance calibration samples are key to advancing the research-to-manufacturing process of nanoscale devices and materials through calibrated, reliable, and comparable measurements. No such calibration reference samples have been proposed so far. In this work, we demonstrate the development of a multi-resistance reference sample for calibrating resistance measurements in conductive probe atomic force microscopy (C-AFM) covering the range from 100 Ω to 100 GΩ. We present a comprehensive protocol for in situ calibration of the whole measurement circuit encompassing the tip, the current sensing device, and the system controller. Furthermore, we show that our developed resistance reference enables the calibration of C-AFM with a combined relative uncertainty (given at one standard deviation) lower than 2.5% over an extended range from 10 kΩ to 100 GΩ and lower than 1% for a reduced range from 1 MΩ to 50 GΩ. Our findings break through the long-standing bottleneck in C-AFM measurements, providing a universal means for adopting calibrated resistance measurements at the nanoscale in the industrial and academic research and development sectors.

Indexed as

calibrationconductive probe atomic force microscopymeasurement protocolnanoscaleresistance reference

Identifiers

PMID38034476
PMCPMC10682512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.