Evidence map›Paper›PMID 38034374›Full record

ArticleFrontiers in cardiovascular medicine2023

Implementation of the multielectrode radiofrequency-balloon in real-world clinical practice-operator learning curve and procedural outcome at a high-volume center.

Maura M Zylla, Lydia Starrach, Ann-Kathrin Rahm, Dierk Thomas, Norbert Frey, Patrick Lugenbiel

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Maura M ZyllaDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.
Lydia StarrachDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.
Ann-Kathrin RahmDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.
Dierk ThomasDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.
Norbert FreyDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.
Patrick LugenbielDepartment of Cardiology, Medical University Hospital, Heidelberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The novel multielectrode radiofrequency (RF) balloon catheter (HELIOSTAR™, Biosense Webster) is a new technology for pulmonary vein isolation (PVI) in atrial fibrillation (AF), combining RF-ablation and 3D-mapping visualization with the concept of a "single-shot"-ablation device. This study evaluates the operator learning curve und procedural outcome during implementation of the multielectrode RF-balloon at a high-volume center. Methods: The first 40 patients undergoing PVI by multielectrode RF-balloon catheter at Heidelberg University Hospital were included in this prospective study. Procedural outcome was analyzed over the course of increasing experience with the device. Results: 157/157 pulmonary veins (PVs) were successfully isolated with the RF-balloon catheter, in 73.2% by a single RF-application. Median time to isolation (TTI) was 11.0 s (Q1 = 8.0 s; Q3 = 13.8 s). Median procedure time was 62.5 min (Q1 = 50.0 min; Q3 = 70.5 min). LA-dwell time was 28.5 min (Q1 = 23.3 min; Q3 = 36.5 min). Median fluoroscopy duration was 11.6 min (Q1 = 10.1 min; Q3 = 13.7 min). No serious procedure-related complications were observed, apart from one case of unclear, post-procedural acute-on-chronic kidney injury. With increasing operator experience, an additional reduction in procedure duration was observed. Conclusion: Rapid implementation of a "single shot"-ablation device combining RF-ablation and 3D-mapping can be achieved with high acute procedural efficacy and safety at a high-volume center. Previous experience with "single-shot" ablation devices may be advantageous for time-efficient introduction of the novel RF-balloon catheter into clinical practice. Clinical Trial Registration: ClinicalTrials.gov; Identifier NCT0560361.

Indexed as

atrial fibrillationcatheter ablationoperator learning curvepulmonary vein isolationradiofrequency balloon

Identifiers

PMID38034374
PMCPMC10682364

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.