Modification of titanium orthopedic implants with bioactive glass: a systematic review of
Synthesis in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- AI for bioactive materials: From material design to biological applications.Bioactive materials · 2026Review
- Antimicrobial efficiency of pH-responsive PAA/PAH-coated and flucloxacillin loaded titanium implants in the Galleria mellonella model.Drug delivery and translational research · 2026Article
- Electrosprayed Chitosan-Calcium Phosphate Microshell Composite Coatings on Silanized Titanium Substrates.Journal of functional biomaterials · 2026Article
- Antimicrobial Gelatin Methacryloyl (GelMA)/Bioactive Glass Dental Adhesives.Journal of functional biomaterials · 2026Article
- Toward next-generation hip implants: From failure mechanisms to translational design.Journal of orthopaedic translation · 2026Review
- Ti6Al4V-Bioglass-Copper Composites for Load-Bearing Implants.Advanced healthcare materials · 2026Article
- Biocompatible Thin Films Deposited by Laser Techniques.Materials (Basel, Switzerland) · 2026Review
- Bioactive glass S53P4 cream kills ESKAPE panel multidrug resistant pathogens andFrontiers in pharmacology · 2026Article
- Bioactive Ti-3Cu alloys with starch, mesoporous bioactive glass nanoparticles, and clove coating for enhanced orthopedic applications.RSC advances · 2025Article
- The Future of Dental Implants: A Narrative Review of Trends, Technologies, and Patient Considerations.Cureus · 2025Review
- Bioactive Glass and Melittin Thin Films Deposited by MAPLE for Titanium Implant Functionalization.Materials (Basel, Switzerland) · 2025Article
- Enhanced Bioactivity of Cu-Doped Bioactive Glass Coatings on Human Freeze-Dried Cortical Bone: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2025Article
- Properties and antibacterial effectiveness of metal-ion doped borate-based bioactive glasses.Future microbiology · 2025Review
- Aluminum-Free Borosilicate Glass Functionalized Hydrogels for Enhanced Dental Tissue Regeneration.Materials (Basel, Switzerland) · 2024Article
- Comparison of Biocompatibility of 3D-Printed Ceramic and Titanium in Micropig Ankle Hemiarthroplasty.Biomedicines · 2024Article
- Critical-sized marginal defects around implants in the rabbit mandible.Oral and maxillofacial surgery · 2024Article
- Biomineral-Based Composite Materials in Regenerative Medicine.International journal of molecular sciences · 2024Review
- Temporary Anchorage Devices in Combined Treatments: Bridging Orthodontics and Prosthetics : Temporary Anchorage Devices in Combined Treatments.Galen medical journal · 2024Review
- Innovations in Dental Implants Integration: Optimizing dental implants performance utilizing stem cells and coatings.Biotechnology progressReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Bioactive glasses (BGs) are ideal biomaterials in the field of bio-restoration due to their excellent biocompatibility. Titanium alloys are widely used as a bone graft substitute material because of their excellent corrosion resistance and mechanical properties; however, their biological inertness makes them prone to clinical failure. Surface modification of titanium alloys with bioactive glass can effectively combine the superior mechanical properties of the substrate with the biological properties of the coating material. In this review, the relevant articles published from 2013 to the present were searched in four databases, namely, Web of Science, PubMed, Embase, and Scopus, and after screening, 49 studies were included. We systematically reviewed the basic information and the study types of the included studies, which comprise