Evidence map›Paper›PMID 38032780›Full record

ArticleIEEE transactions on bio-medical engineering2024

In Vivo Optical Coherence Elastography Unveils Spatial Variation of Human Corneal Stiffness.

Guo-Yang Li, Xu Feng, Seok-Hyun Yun

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Guo-Yang Li
Xu Feng
Seok-Hyun Yun
Harvard University · US

Funding

In vivo high-resolution mapping of the elastic moduli and tensile stress in the human corneaR01EY034857 · NEI · MASSACHUSETTS GENERAL HOSPITAL · PI Seok-Hyun Andy Yun · 2023 to 2026
$2.1M
Development of stimulated Brillouin microscopy for high-resolution stiffness measurementR01EB027653 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI YUN, SEOK-HYUN ANDY · 2019 to 2023
$2.0M
In vivo optical coherence elastography of the cornea: mapping shear and tensile moduliR01EY033356 · NEI · MASSACHUSETTS GENERAL HOSPITAL · PI YUN, SEOK-HYUN ANDY · 2022 to 2024
$1.2M
NEI NIH HHS R01 EY033356NEI NIH HHS R01 EY034857NIBIB NIH HHS R01 EB027653
6 · The paper itself

Abstract

objectiveThe mechanical properties of corneal tissues play a crucial role in determining corneal shape and have significant implications in vision care. This study aimed to address the challenge of obtaining accurate in vivo data for the human cornea.

methodsWe have developed a high-frequency optical coherence elastography (OCE) technique using shear-like antisymmetric (A0)-mode Lamb waves at frequencies above 10 kHz.

resultsBy incorporating an anisotropic, nonlinear constitutive model and utilizing the acoustoelastic theory, we gained quantitative insights into the influence of corneal tension on wave speeds and elastic moduli. Our study revealed significant spatial variations in the shear modulus of the corneal stroma on healthy subjects for the first time. Over an age span from 21 to 34 (N = 6), the central corneas exhibited a mean shear modulus of 87 kPa, while the corneal periphery showed a significant decrease to 44 kPa. The central cornea's shear modulus decreases with age with a slope of -19 +/- 8 kPa per decade, whereas the periphery showed non-significant age dependence. The limbus demonstrated an increased shear modulus exceeding 100 kPa. We obtained wave displacement profiles that are consistent with highly anisotropic corneal tissues.

conclusionOur approach enabled precise measurement of corneal tissue elastic moduli in situ with high precision (<7%) and high spatial resolution (<1 mm). Our results revealed significant stiffness variation from the central to peripheral corneas. SIGNIFICANCE: The high-frequency OCE technique holds promise for biomechanical evaluation in clinical settings, providing valuable information for refractive surgeries, degenerative disorder diagnoses, and intraocular pressure assessments.

Indexed as

CorneaElasticity Imaging TechniquesElastic ModulusTomography, Optical CoherenceAdultFemaleHumansMaleModels, BiologicalYoung Adult

Identifiers

PMID38032780
PMCPMC11086014
OpenAlexW4389169172

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.