Evidence map›Paper›PMID 38032446›Full record

ArticleJournal of experimental orthopaedics2023

Superior bone fixation of conical compared with hemispherical trapezial cup design: an experimental radiostereometry study.

Maiken Stilling, Lene Dremstrup, Torben Bæk Hansen, Janni Kjærgaard Thillemann

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Development of small bone implants using a mean shape bone in a porcine model for carpal bone replacement.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2025
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Maiken StillingDepartment of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165 J801, DK- 8200, Aarhus N, Denmark. maiken.stilling@clin.au.dk.ORCID http://orcid.org/0000-0002-4530-2075
Lene DremstrupDepartment of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning, Denmark.
Torben Bæk HansenDepartment of Clinical Medicine, Aarhus University, Aarhus N, Denmark.
Janni Kjærgaard ThillemannDepartment of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165 J801, DK- 8200, Aarhus N, Denmark.
Aarhus University · DKRegionshospitalet Herning · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe most used cup designs for trapeziometacarpal (TMC) arthroplasty are of hemispherical and conical geometrical shape. Using a validated pig bone model, we compared the bone fixation using radiostereometry (RSA).

methodsTwenty saddle-shaped pig forefoot bones were prepared with insertion of bone markers and reaming. Hemispherical Type T cups (Beznoska, Kladno, Czech Republic) (N = 10) and conical Moovis cups (Stryker, Pusignan, France) (N = 10) of 9-mm diameter were inserted press-fit. The bones were fixed in cement blocks for stability, and the cups were loaded in a motorized test stand. First, a low-pressure cyclic load test (0-150N) with 130 compression cycles was performed. Next, a push-in test of progressive loads with 50N increments (range: 150-900N) was applied until a visual change in cup position appeared. Cup migration was evaluated with RSA after every new load application. Cup failure was defined as total translation > 0.5 mm between two load applications.

resultsBoth cup types tolerated a compression load of 450 N without failure. Beyond this load level, the total translation cup migration of mean 0.20 mm (95% CI 0.11; 0.30) for the Type T group was higher than mean 0.10 mm (95% CI 0.06; 0.15) of the Moovis group (p = 0.046). The Hazard ratio for failure was 0.52 (95% CI 0.12; 2.17) (p = 0.37), indicating that the risk of failure was two-fold higher in the Type T group.

conclusionWe conclude that conical TMC cups have superior fixation as compared to hemispherical cups above a loading level of 450 N, which correspond to a 3.8 kg tip-pinch. In a clinical perspective, based on the fixation strength of both cup types, it seems safe to allow light-load activities of daily living such as buttoning a shirt and using a key shortly after surgery and until sufficient osseointegration is achieved.

Indexed as

Conical cupCup fixationHemispherical cupRadiostereometryTrapeziometacarpal arthroplastyTrapeziometacarpal osteoarthritis

Identifiers

PMID38032446
PMCPMC10689311
OpenAlexW4389179955

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.