Evidence map›Paper›PMID 38032122›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Unlocking Diabetic Acetone Vapor Detection by A Portable Metal-Organic Framework-Based Turn-On Optical Sensor Device.

Samraj Mollick, Sujeet Rai, Louis Frentzel-Beyme, Vishal Kachwal, Lorenzo Donà, Dagmar Schürmann, Bartolomeo Civalleri, Sebastian Henke, Jin-Chong Tan

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Exploring the Photophysical and Mechanical Behavior of Fluorescent Metal-Organic Framework Monoliths.Chemistry of materials : a publication of the American Chemical Society · 2024
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Samraj MollickMultifunctional Materials & Composites (MMC) Laboratory, Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1, UK.ORCID https://orcid.org/0000-0002-8617-6343
Sujeet RaiMultifunctional Materials & Composites (MMC) Laboratory, Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1, UK.
Louis Frentzel-BeymeAnorganische Chemie, Fakultät für Chemie & Chemische Biologie, Tec-hnische Universität Dortmund, Otto-Hahn Straße 6, 44227, Dortmund, Germany.
Vishal KachwalMultifunctional Materials & Composites (MMC) Laboratory, Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1, UK.
Lorenzo DonàDepartment of Chemistry, University of Turin, Via Pietro. Giuria 5, Torino, 10125, Italy.
Dagmar SchürmannAnorganische Chemie, Fakultät für Chemie & Chemische Biologie, Tec-hnische Universität Dortmund, Otto-Hahn Straße 6, 44227, Dortmund, Germany.
Bartolomeo CivalleriDepartment of Chemistry, University of Turin, Via Pietro. Giuria 5, Torino, 10125, Italy.
Sebastian HenkeAnorganische Chemie, Fakultät für Chemie & Chemische Biologie, Tec-hnische Universität Dortmund, Otto-Hahn Straße 6, 44227, Dortmund, Germany.
Jin-Chong TanMultifunctional Materials & Composites (MMC) Laboratory, Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1, UK.ORCID https://orcid.org/0000-0002-5770-408X
University of Oxford · GBTU Dortmund University · DEUniversity of Turin · IT

Funding

European Research Council 771575
6 · The paper itself

Abstract

Despite exhaled human breath having enabled noninvasive diabetes diagnosis, selective acetone vapor detection by fluorescence approach in the diabetic range (1.8-3.5 ppm) remains a long-standing challenge. A set of water-resistant luminescent metal-organic framework (MOF)-based composites have been reported for detecting acetone vapor in the diabetic range with a limit of detection of 200 ppb. The luminescent materials possess the ability to selectively detect acetone vapor from a mixture comprising nitrogen, oxygen, carbon dioxide, water vapor, and alcohol vapor, which are prevalent in exhaled breath. It is noteworthy that this is the first luminescent MOF material capable of selectively detecting acetone vapor in the diabetic range via a turn-on mechanism. The material can be reused within a matter of minutes under ambient conditions. Industrially pertinent electrospun luminescent fibers are likewise fabricated alongside various luminescent films for selective detection of ultratrace quantities of acetone vapor present in the air. Ab initio theoretical calculations combined with in situ synchrotron-based dosing studies uncovered the material's remarkable hypersensitivity toward acetone vapor. Finally, a freshly designed prototype fluorescence-based portable optical sensor is utilized as a proof-of-concept for the rapid detection of acetone vapor within the diabetic range.

Indexed as

acetone sensingmetal-organic frameworks (MOFs)nanospectroscopyoptical sensorsphotoluminescence

Identifiers

PMID38032122
PMCPMC10811499
OpenAlexW4389179142

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.