Evidence map›Paper›PMID 38030864›Full record

Observational studyLangenbeck's archives of surgery2023

Valvulotomy of the great saphenous vein in ex situ non-reversed and in situ setting: a multicenter post-market study to assess the safety and efficacy of the AndraValvulotome™".

Yaser Souri, Dominik Liebetrau, Alexander Hyhlik-Dürr, Vascular Investigators

Open access · hybridAbstract readObservational StudyMulticenter Study
In one paragraph

Observational study in Langenbeck's archives of surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Yaser SouriVascular and Endovascular Surgery, Medical Faculty, University of Augsburg, Stenglinstrasse 2, 86156, Augsburg, Germany. yaser.souri@uk-augsburg.de.ORCID http://orcid.org/0009-0002-0496-2859
Dominik LiebetrauVascular and Endovascular Surgery, Medical Faculty, University of Augsburg, Stenglinstrasse 2, 86156, Augsburg, Germany.
Alexander Hyhlik-DürrVascular and Endovascular Surgery, Medical Faculty, University of Augsburg, Stenglinstrasse 2, 86156, Augsburg, Germany.
Vascular Investigators
University of Augsburg · DEGoethe University Frankfurt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the safety and technical success of the AndraValvulotome™ device (Andramed GmbH, Reutlingen, Germany) in patients with peripheral arterial disease (PAD) requiring bypass surgery using the great saphenous vein (GSV) as graft.

methodsThis was a multicenter, post-market observational study conducted in 2021 in 11 German centers. Safety and efficacy data were prospectively collected and analyzed. Primary endpoints were the absence of device-related serious adverse events until 30 ± 7 days follow-up, the clinical efficacy of valvulotomy, which was defined as pulsatile blood flow in the bypass and the number of insufficiently destroyed vein valves. Secondary endpoints were the number of valvulotomy passages, the primary patency rate of the venous bypass (determined by a color-duplex sonography showing a normal blood flow through the bypass and absence of stenosis or occlusion), and the primary technical success defined as the absence of product-specific (serious) adverse events and clinical efficacy.

resultsFifty-nine patients were enrolled. The mean age of the patients was 71 years (46-91), and 74.6% were males. The vein material used for bypass grafting had a median length of 47.5 cm (range 20-70 cm) with a median diameter of 5.0 mm (range 3-6 mm) and 4.0 mm (range 2-6 mm) in the proximal and distal segments, respectively. The technical success rate was 96.6%. The primary patency rate was 89.9% at 30 days follow-up. The clinical efficacy was rated as very good in 81% of patients, fair in 17%, and poor in 2%. Between 1 and 5 (average 2.9) valvulotome passages were performed. One product-related serious adverse event was recorded (bypass vein dissection).

conclusionThe AndraValvulotome™ can be considered a safe and effective device to disrupt venous valves during in situ non-reversed bypass surgeries using GSV grafts in patients with PAD.

Indexed as

Saphenous VeinVascular Surgical ProceduresAgedAged, 80 and overFemaleHumansMaleMiddle AgedTreatment OutcomeUltrasonography, Doppler, DuplexVascular PatencyBypass surgeryGreat saphenous vein bypassInfrainguinal bypassNon-reversed bypassValvulotomy

Identifiers

PMID38030864
PMCPMC10687093
OpenAlexW4389153496

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.