ArticleHeliyon2023
Reliability, accuracy, and minimal detectable difference of a mixed concept marker set for finger kinematic evaluation.
Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Proof of Concept and Validation of Single-Camera AI-Assisted Live Thumb Motion Capture.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The study of finger biomechanics requires special tools for accurately recording finger joint data. A marker set to evaluate finger postures during activities of daily living is needed to understand finger biomechanics in order to improve prosthesis design and clinical interventions. The purpose of this study was to evaluate the reliability of a proposed hand marker set (the Warwick marker set) to capture finger kinematics using motion capture. The marker set consisted of the application of two and three marker clusters to the fingers of twelve participants who participated in the tests across two sessions. Calibration markers were applied using a custom palpation technique. Each participant performed a series of range of motion movements and held a set of objects. Intra and inter-session reliability was calculated as well as Standard Error of Measurement (SEM) and Minimal Detectable Difference (MDD). The findings showed varying levels of intra- and inter-session reliability, ranging from poor to excellent. The SEM and MDD values were lower for the intra-session range of motion and grasp evaluation. The reduced reliability can potentially be attributed to skin artifacts, differences in marker placement, and the inherent kinematic variability of finger motion. The proposed marker set shows potential to assess finger postures and analyse activities of daily living, primarily within the context of single session tests.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.