Evidence map›Paper›PMID 38026464›Full record

Trial reportJournal of pain research2023

Dural Puncture Epidural with 25-G Spinal Needles versus Conventional Epidural Technique in Conjunction with PIEB for Labor Analgesia: A Randomized Trial.

Wenqian Lin, Yongyong Yang, Jun Lin, Jianxing Chen, Qun Lin

Registry-linked trialAbstract readCase ReportsClinical Trial
In one paragraph

Trial report in Journal of pain research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06849726 (Comparison of Standard Epidural and Dural Puncture Epidural Techniques in Labor Analgesia), which is not on this map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06849726 completednot on this mapstarted 2025, after this paper: background citation

Comparison of Standard Epidural and Dural Puncture Epidural Techniques in Labor Analgesia

TypeobservationalSponsorMedipol UniversityRan2025 to 2025Enrolled100ConditionsLabor Pain, Epidural AnalgesiaArmsStandard Epidural Analgesia, Dural Puncture Epidural Analgesia
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wenqian LinDepartment of Anesthesiology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, People's Republic of China.ORCID 0000-0002-3480-3229
Yongyong YangDepartment of Anesthesiology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, People's Republic of China.
Jun LinDepartment of Anesthesiology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, People's Republic of China.
Jianxing ChenDepartment of Anesthesiology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, People's Republic of China.
Qun LinDepartment of Anesthesiology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To compare the effect of Dural puncture epidural (DPE) and conventional epidural (EP), in conjunction with programmed intermittent epidural bolus (PIEB) and low-concentration ropivacaine strategy. Methods: After written informed consent was obtained, healthy nulliparous women with singleton pregnancies, vertex presentation at 38-42 weeks' gestation, cervical dilation of 3-5 cm, and a desire for pain relief were randomly assigned to DPE or EP group. Dural matter was puncture with 25G Whitacre needle in DPE group. Analgesia was initiated with 15 mL of 0.1% ropivacaine over 5 minutes and was maintained by PIEB (8 mL of 0.08% ropivacaine with 2 μg/mL fentanyl every 40 min). Primary outcome was the percentage of adequate analgesia, defined as NRPS ≤1, at 30 minutes after the initiation of the epidural bolus. Results: Out of 130 enrolled parturients, 127 were included in final analysis (64 in DPE group, 63 in EP group). No significant difference was found in percentage of adequate analgesia at 30 minutes (risk ratio: 1.09; 95% confidence interval: 0.90-1.31; Conclusion: The combination of the use of DPE technique with 25G spinal needle and PIEB technique for labor analgesia appears to enhance the quality of labor analgesia by accelerating onset and providing improved sacral blockade, without increasing adverse effects.

Indexed as

dural puncture epidurallabor analgesiaprogrammed intermittent bolusropivacaine

Identifiers

PMID38026464
PMCPMC10640826

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.