Evidence map›Paper›PMID 38025965›Full record

ArticleInternational journal of biomedical imaging2023

Assessment of the Impact of Turbo Factor on Image Quality and Tissue Volumetrics in Brain Magnetic Resonance Imaging Using the Three-Dimensional T1-Weighted (3D T1W) Sequence.

Eric Naab Manson, Stephen Inkoom, Abdul Nashirudeen Mumuni, Issahaku Shirazu, Adolf Kofi Awua

Abstract read
In one paragraph

Article in International journal of biomedical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eric Naab MansonDepartment of Medical Imaging, School of Allied Health Sciences, University for Development Studies, Tamale, Ghana.ORCID https://orcid.org/0000-0003-1591-7922
Stephen InkoomRadiation Protection Institute (RPI), Ghana Atomic Energy Commission, Accra, Ghana.
Abdul Nashirudeen MumuniDepartment of Medical Imaging, School of Allied Health Sciences, University for Development Studies, Tamale, Ghana.ORCID https://orcid.org/0000-0003-4697-0654
Issahaku ShirazuRadiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, Accra, Ghana.
Adolf Kofi AwuaRadiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, Accra, Ghana.ORCID https://orcid.org/0000-0003-2516-4514

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The 3D T1W turbo field echo sequence is a standard imaging method for acquiring high-contrast images of the brain. However, the contrast-to-noise ratio (CNR) can be affected by the turbo factor, which could affect the delineation and segmentation of various structures in the brain and may consequently lead to misdiagnosis. This study is aimed at evaluating the effect of the turbo factor on image quality and volumetric measurement reproducibility in brain magnetic resonance imaging (MRI). Methods: Brain images of five healthy volunteers with no history of neurological diseases were acquired on a 1.5 T MRI scanner with varying turbo factors of 50, 100, 150, 200, and 225. The images were processed and analyzed with FreeSurfer. The influence of the TFE factor on image quality and reproducibility of brain volume measurements was investigated. Image quality metrics assessed included the signal-to-noise ratio (SNR) of white matter (WM), CNR between gray matter/white matter (GM/WM) and gray matter/cerebrospinal fluid (GM/CSF), and Euler number (EN). Moreover, structural brain volume measurements of WM, GM, and CSF were conducted. Results: Turbo factor 200 produced the best SNR (median = 17.01) and GM/WM CNR (median = 2.29), but turbo factor 100 offered the most reproducible SNR (IQR = 2.72) and GM/WM CNR (IQR = 0.14). Turbo factor 50 had the worst and the least reproducible SNR, whereas turbo factor 225 had the worst and the least reproducible GM/WM CNR. Turbo factor 200 again had the best GM/CSF CNR but offered the least reproducible GM/CSF CNR. Turbo factor 225 had the best performance on EN (-21), while turbo factor 200 was next to the most reproducible turbo factor on EN (11). The results showed that turbo factor 200 had the least data acquisition time, in addition to superior performance on SNR, GM/WM CNR, GM/CSF CNR, and good reproducibility characteristics on EN. Both image quality metrics and volumetric measurements did not vary significantly ( Conclusion: Since no significant differences were observed in the performance of the turbo factors in terms of image quality and volume of brain structure, turbo factor 200 with a 74% acquisition time reduction was found to be optimal for brain MR imaging at 1.5 T.

Identifiers

PMID38025965
PMCPMC10665095

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.