Evidence map›Paper›PMID 38019446›Full record

ArticlePhysical and engineering sciences in medicine2024

A prospective comparative study on bladder volume measurement with portable ultrasound scanner and CT simulator in pelvic tumor radiotherapy.

Fei Bai, Qiuxia Hu, Xiaowei Yao, Ming Cheng, Lina Zhao, Linlin Xu

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. The impact of sex on setup accuracy in radiotherapy for rectal cancer: a real-World observational study.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
    Observational
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fei Bai *Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China.
Qiuxia Hu *Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China.
Xiaowei YaoDepartment of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China.
Ming ChengDepartment of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China.
Lina ZhaoDepartment of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China. zhaolina@fmmu.edu.cn.
Linlin XuDepartment of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, Shaanxi, China. 1834763956@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe consistency of bladder volume is very important in pelvic tumor radiotherapy, and portable bladder scanner is a promising device to measure bladder volume. The purpose of this study was to investigate whether the bladder volume of patients with pelvic tumor treated with radiotherapy can be accurately measured using the Meike Palm Bladder Scanner PBSV3.2 manufactured in China and the accuracy of its measurement under different influencing factors.

methodsA total of 165 patients with pelvic tumor undergoing radiotherapy were prospectively collected. The bladder volume was measured with PBSV3.2 before simulated localization. CT simulated localization was performed when the bladder volume was 200-400ml. The bladder volume was measured with PBSV3.2 immediately after localization and recorded. The bladder volume was then delineated on CT simulation images and recorded. To compare the consistency of CT simulation bladder volume and bladder volume measured by PBSV3.2. To investigate the accuracy of PBSV3.2 in different sex, age, treatment purpose, and bladder volume.

resultsThere was a significant positive correlation with bladder volume on CT and PBSV3.2 (r = 0.874; p < 0.001). The mean difference between CT measured values and PBSV3.2 was (-0.14 ± 50.17) ml. The results of the different variables showed that the overall mean of PBSV3.2 and CT measurements were statistically different in the age ≥ 65 years, bladder volumes > 400ml and ≤ 400ml groups (p = 0.028, 0.002, 0.001). There was no statistical significance between the remaining variables. The volume difference between PBSV3.2 measurement and CT was 12.87ml in male patients, which was larger than that in female patients 3.27ml. Pearson correlation analysis showed that the correlation coefficient was 0.473 for bladder volume greater than 400ml and 0.868 for bladder volume less than 400ml; the correlation coefficient of the other variables ranged from 0.802 to 0.893.

conclusionThis is the first large-sample study to evaluate the accuracy of PBSV3.2 in a pelvic tumor radiotherapy population using the convenient bladder scanner PBSV3.2 made in China. PBSV3.2 provides an acceptable indicator for monitoring bladder volume in patients with pelvic radiotherapy. It is recommended to monitor bladder volume with PBSV3.2 when the planned bladder volume is 200-400ml. For male and patients ≥ 65 years old, at least two repeat measurements are required when using a bladder scanner and the volume should be corrected by using a modified feature to improve bladder volume consistency.

Indexed as

Pelvic NeoplasmsUrinary BladderAgedChinaFemaleHumansMaleProspective StudiesTomography, X-Ray ComputedBladder volumePelvic neoplasmPortable bladder scannerRadiation therapy

Identifiers

PMID38019446
PMCPMC10963561

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.