Evidence map›Paper›PMID 38018758›Full record

ArticleJournal of applied clinical medical physics2024

A robust treatment planning approach for chest motion in postmastectomy chest wall intensity modulated radiation therapy.

Yuya Miyasaka, Takuya Ono, Hongbo Chai, Hikaru Souda, Sung Hyun Lee, Miyu Ishizawa, Hiroko Akamatsu, Hiraku Sato, Takeo Iwai

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Yuya MiyasakaDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Takuya OnoDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Hongbo ChaiDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Hikaru SoudaDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Sung Hyun LeeDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Miyu IshizawaDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Hiroko AkamatsuDepartment of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan.
Hiraku SatoDepartment of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan.
Takeo IwaiDepartment of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Yamagata University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeChest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error. MATERIAL AND

methodsThis study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan.

resultNo significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP.

conclusionWe revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.

Indexed as

Breast NeoplasmsRadiotherapy, Intensity-ModulatedThoracic WallFemaleHumansMastectomyRadiotherapy DosageRadiotherapy Planning, Computer-AssistedIMRTPMRTrespiratory motionrobust optimizationsetup error

Identifiers

PMID38018758
PMCPMC10795451
OpenAlexW4389140257

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.