Evidence map›Paper›PMID 38018073›Full record

ArticleClinical and experimental emergency medicine2024

Development and demonstration of the protective efficacy of a convertible respiratory barrier enclosure: a simulation study.

Min Ho Park, Ki Sub Sung, Ji Hoon Kim, Jinwoo Myung, Ju Young Hong

Open access · diamondAbstract read
In one paragraph

Article in Clinical and experimental emergency medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Min Ho ParkDepartment of Emergency Medicine, Yonsei University College of Medicine, Seoul, Korea.
Ki Sub SungSS-ENG Co Ltd, Bucheon, Korea.
Ji Hoon KimDepartment of Emergency Medicine, Yonsei University College of Medicine, Seoul, Korea.
Jinwoo MyungDepartment of Emergency Medicine, Yonsei University College of Medicine, Seoul, Korea.
Ju Young HongDepartment of Emergency Medicine, Yonsei University College of Medicine, Seoul, Korea.
Yonsei University · KRThe Catholic University of Korea Bucheon St. Mary's Hospital · KR

Funding

Korea Health Industry Development Institute HG22C0001
6 · The paper itself

Abstract

objectiveThe efficacy of previously developed respiratory barrier enclosures to limit healthcare workers' exposure to aerosols from COVID-19 patients remains unclear; in addition, the design of these devices is unsuitable for transportation or other emergency procedures. Therefore, we developed a novel negative pressure respiratory isolator to improve protection from patient-generated aerosols and evaluated its protective effect in conversion to systemic isolator.

methodsThis in vitro study simulated droplets by nebulizing 1% glycerol + 99% ethanol solution. We performed cardiopulmonary resuscitation (CPR) and converted a respiratory barrier enclosure into a systemic isolator with a respiratory barrier as well as a respiratory barrier with negative pressure generator (NPG), which were compared with control and room air. During the procedure, particles were counted for 30 seconds and the count was repeated 10 times.

resultsDuring CPR, the total number of particles in the respiratory barrier with NPG (280,529; interquartile range [IQR], 205,263-359,195; P=0.970) was similar to that in the control (308,789; IQR, 175,056-473,276). Using NPG with a respiratory barrier reduced the number of particles to 27,524 (IQR, 26,703- 28,905; P=0.001). Particle number during conversion of the respiratory barrier into a systemic isolator was also lower than in the control (25,845; IQR, 19,391- 29,772; P=0.001).

conclusionThe novel isolator was converted to a systemic isolator without air leakage. The aerosol-blocking effect of the isolator was quantified using a particle counter during CPR. Further studies comparing the barrier effect of isolators within various pressure differentials are warranted.

Indexed as

Aerosol boxCardiopulmonary resuscitationInfection controlIntubationPersonal protective equipment

Identifiers

PMID38018073
PMCPMC11009702
OpenAlexW4389147454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.