ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026
Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Multicenter experience of the Monopoint reperfusion system in acute large vessel occlusion stroke thrombectomy.Journal of neurointerventional surgery · 2026Article
- Balancing flow arrest and aspiration: The relationship between balloon guide catheters, large-bore aspiration, and first pass effect in mechanical thrombectomy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- A single-center study of the RED 72 reperfusion catheter with SENDit technology in proximal large vessel occlusions.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Microguidewire stiffness for microcatheter and aspiration catheter navigation in tortuous vessels.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Tenzing Assisted Delivery of Aspiration (TADA) technique for thrombectomy of medium vessel occlusions using the Freeclimb 54 catheter: multicenter experience.Journal of neurointerventional surgery · 2025Article
- Atrial fibrillation is associated with lower likelihood of first-pass effect in thrombectomy for medium vessel occlusion acute ischemic strokes.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Venous Sinus Stenting Using a Ledge-Reducing Catheter, 0.088-in. Catheter-Extender With an External Single Point of Control: Technique and Multicenter Clinical Experience.Stroke (Hoboken, N.J.) · 2025Article
- Tenzing 7 Delivery Catheter Performance Across Tortuosity Indices.Stroke (Hoboken, N.J.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
IntroductionAspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire.MethodsA retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate.ResultsA leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46).ConclusionIn our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials