Evidence map›Paper›PMID 38018015›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026

Utilisation of the Scepter Mini dual-lumen balloon - An illustrative series.

Sean Thomas O'Reilly, Eef Jacobus Hendriks, Ze'ev Itsekson, Rabab Alshahrani, Emily Chung, Ivan Radovanovic, Ronit Agid, Patrick Nicholson, Timo Krings

Open access · hybridAbstract readCase Reports
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 2 countries.

Sean Thomas O'ReillyDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.ORCID 0000-0003-1023-5471
Eef Jacobus HendriksDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Ze'ev ItseksonDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.ORCID 0000-0001-8320-4129
Rabab AlshahraniDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Emily ChungDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Ivan RadovanovicDepartment of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Ronit AgidDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Patrick NicholsonDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
Timo KringsDivision of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.
University Health Network · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundDual-lumen balloon microcatheters can aid in the safety and efficacy of endovascular embolisation of cerebrospinal vascular malformations. The Scepter Mini dual-lumen balloon is a novel device with a smaller profile than previous balloon microcatheters, opening up new indications not only in the treatment of cerebrospinal malformations but in various other neurovascular therapeutic and diagnostic scenarios.MethodsFollowing institutional ethics review board approval, a retrospective review of our prospectively maintained database of cases employing the Scepter Mini dual-lumen microballoon catheter was conducted. Five cases in particular were highlighted, demonstrating utilisation of this device, which may be of interest to the Neurointerventionalist. Patient demographics, procedure details, complications and clinical outcome data were reviewed.ResultsFive cases employing the Scepter Mini dual-lumen microballoon catheter are presented; trans-arterial embolisation of cerebral AVM, pre-operative tumour embolisation, diagnostic angiography, trans-venous embolisation of cerebral AVM and trans-arterial embolisation of DAVF. No intraprocedural complications were recorded, one patient had a delayed haemorrhage.ConclusionPotential utilisation of the Scepter Mini lies not only in the trans-arterial embolisation of cerebrospinal vascular malformations, but in a range of other diagnostic and therapeutic indications as demonstrated.

Indexed as

Balloon OcclusionCentral Nervous System Vascular MalformationsEmbolization, TherapeuticIntracranial Arteriovenous MalformationsCerebral AngiographyEquipment DesignHumansRetrospective StudiesTreatment OutcomeArteriovenous malformationballoon micro cathetercerebral angiographydural arteriovenous fistulaembolisation

Identifiers

PMID38018015
PMCPMC13294577
OpenAlexW4389149332

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.