Evidence map›Paper›PMID 38017199›Full record

ArticlePediatric cardiology2024

Intracardiac Three-Dimensional Image as Surgical Decision-Making Tool of Congenital Heart Disease.

Sho Isobe, Yuzo Katayama, Tsukasa Ozawa, Takeshiro Fujii

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. HoloPatch: improving intracardiac patch fit through holographically modelled templates.European heart journal. Imaging methods and practice · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sho IsobeDivision of Cardiovascular Surgery, Department of Surgery, Toho University Omori Medical Center, 6-11 Omori-Nishi Ota-Ku, Tokyo, 143-8541, Japan.ORCID http://orcid.org/0009-0008-5651-9430
Yuzo KatayamaDivision of Cardiovascular Surgery, Department of Surgery, Toho University Omori Medical Center, 6-11 Omori-Nishi Ota-Ku, Tokyo, 143-8541, Japan. yuuzou.katayama@med.toho-u.ac.jp.ORCID http://orcid.org/0000-0002-2206-8212
Tsukasa OzawaDivision of Cardiovascular Surgery, Department of Surgery, Toho University Omori Medical Center, 6-11 Omori-Nishi Ota-Ku, Tokyo, 143-8541, Japan.ORCID http://orcid.org/0009-0001-7753-9982
Takeshiro FujiiDivision of Cardiovascular Surgery, Department of Surgery, Toho University Omori Medical Center, 6-11 Omori-Nishi Ota-Ku, Tokyo, 143-8541, Japan.ORCID http://orcid.org/0009-0009-6523-6325
Toho University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to evaluate the anatomical reproducibility of a preoperative intracardiac 3D image (IC image) created using computed tomography, and to investigate its usefulness as a surgical decision-making tool. Between 2012 and 2022, ventricular septal defect (VSD) patients, and double outlet right ventricle (DORV) or transposition of the great arteries (TGA) with pulmonary stenosis (PS) patients who underwent cardiac surgery and had preoperative computed tomography were enrolled. SYNAPSE VINCENT® (Fujifilm) was used to create an IC image which was analyzed retrospectively. In 14 VSD patients, the diagnostic consistency rate in the Soto classification with intraoperative findings was 100% (14/14) for IC image versus 64% (9/14) for transthoracic echocardiography (P = 0.04). The defect size showed a higher correlation coefficient with IC image (0.837, P = 0.001) than with transthoracic echocardiography (0.567, P = 0.034). In 11 DORV/TGA with PS patients, the diagnostic consistency rate in the Lev classification was 100% (9/9) for IC image versus 77% (7/9) for transthoracic echocardiography (P = 0.47). The secondary interventricular foramen (SVF)/left ventricular outflow tract (LVOT) ratio by IC image was significantly smaller in the biventricular-repair group (median 0.71, IQR 0.67-1.06) than in the univentricular-repair group (median 1.79, IQR 1.53-2.42) (P = 0.006). An IC image is useful as a surgical decision-making tool for simple VSDs and complex congenital heart diseases such as DORV or TGA with pulmonary stenosis. The SVF/LVOT ratio determined from the IC image may be a useful indicator for avoiding LVOT obstruction.

Indexed as

Double Outlet Right VentricleHeart Defects, CongenitalHeart Septal Defects, VentricularPulmonary Valve StenosisTransposition of Great VesselsHumansImaging, Three-DimensionalInfantReproducibility of ResultsRetrospective StudiesTreatment OutcomeBiventricular repairDouble outlet right ventricleIntracardiac 3D imagePreoperative evaluation

Identifiers

PMID38017199
OpenAlexW4389076808

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.