Analysis of the concurrent validity and reliability of five common clinical goniometric devices.

Sirirat Kiatkulanusorn, Nongnuch Luangpon, Wirasinee Srijunto, Sarawoot Watechagit, Krittipat Pitchayadejanant, Sireetorn Kuharat, O Anwar Bég, Bhornluck Paepetch Suato

3 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
7.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06819397 naactive not recruitingnot on this mapstarted 2024, after this paper: background citation

Effects of Post-Isometric Relaxation Technique Versus Cross Friction Soft Tissue Mobilization on Pain, Range of Motion, and Endurance in Leg Spin Bowlers With Rotator Cuff Strain

TypeinterventionalSponsorRiphah International UniversityRan2024 to 2025Enrolled34ConditionsSports Physical TherapyArmspost isometric relaxation, cross friction soft tissue mobilization
NCT07297485 completednot on this mapstarted 2025, after this paper: background citation

An Observational Cross-Sectional Comparison to Evaluate the Level of Agreement Between Standard Universal Goniometer Measurements and a Squat Height Calculator Algorithm to Determine Squat Position for Isometric Wall Squat Position.

TypeobservationalSponsorNorthumbria UniversityRan2025 to 2026Enrolled21ConditionsWall Squat Position
NCT07477145 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Effect of Body Mind Exercises and Specific Neck Exercises in Chronic Mechanical Neck Pain

TypeinterventionalSponsorCairo UniversityRan2026 to 2026Enrolled80ConditionsNeck Pain MusculoskeletalArmsConventional physical therapy group., Body mind exercises group (mindful aerobic exercises), specific neck exercise group, Combined exercise group.
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Evaluation of The Spurgeon MethodInternational journal of therapeutic massage & bodywork · 2026
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Reliability of A Measuring Tape for Assessing Hip Adduction via Ober's Test.International journal of sports physical therapy · 2025
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Sirirat KiatkulanusornDepartment of Physical Therapy, Faculty of Allied Health Sciences, Burapha University, Chonburi, 20131, Thailand. siriratk@go.buu.ac.th.
Nongnuch LuangponDepartment of Physical Therapy, Faculty of Allied Health Sciences, Burapha University, Chonburi, 20131, Thailand.
Wirasinee SrijuntoDepartment of Physical Therapy, Faculty of Allied Health Sciences, Burapha University, Chonburi, 20131, Thailand.
Sarawoot WatechagitFaculty of Engineering, Mahidol University, Phutthamonthon, Nakhon Pathom, Thailand.
Krittipat PitchayadejanantBurapha University International College, Burapha University, Chonburi, 20131, Thailand.
Sireetorn KuharatCorrosion Lab, Multi-Physical Engineering Sciences Group (MPESG), Department of Mechanical/Aeronautical Engineering, Salford University, 3-08, SEE Building, Manchester, M54WT, UK.
O Anwar BégCorrosion Lab, Multi-Physical Engineering Sciences Group (MPESG), Department of Mechanical/Aeronautical Engineering, Salford University, 3-08, SEE Building, Manchester, M54WT, UK.
Bhornluck Paepetch SuatoDepartment of Physical Therapy, Faculty of Allied Health Sciences, Burapha University, Chonburi, 20131, Thailand. bhornluck@go.buu.ac.th.
Burapha University · THMahidol University · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measurement errors play an important role in the development of goniometric equipment, devices used to measure range of motion. Reasonable validity and reliability are critical for both the device and examiner before and after to testing in human subjects. The objective is to evaluate the concurrent validity and reliability of five different clinical goniometric devices for the purpose of establishing an acceptable measurement error margin for a novel device. We explored the validity and inter- and intrarater reliability scores of five goniometric devices namely (i) the universal goniometer (UG), a two-armed hand-held goniometer, (ii) the inclinometer (IC), featuring a single base, fluid level, and gravity-weighted inclinometer, (iii) the digital inclinometer (DI), functioning as both a DI and dynamometer, (iv) the smartphone application (SA), employing gyroscope-based technology within a smartphone platform application and (v) the modified inclinometer (MI), a gravity pendulum-based inclinometer equipped with a specialized fixing apparatus. Measurements were obtained at 12 standard angles and 8 human shoulder flexion angles ranging from 0° to 180°. Over two testing sessions, 120 standardized angle measurements and 160 shoulder angle measurements from 20 shoulders were repetitively taken by three examiners for each device. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated to assess reliability and validity. Concurrent validity was also evaluated through the execution of the 95% limit of agreement (95% LOA) and Bland-Altman plots, with comparisons made to the UG. The concurrent validity for all device pairs was excellent in both study phases (ICC > 0.99, 95% LOA - 4.11° to 4.04° for standard angles, and - 10.98° to 11.36° for human joint angles). Inter- and intrarater reliability scores for standard angles were excellent across all devices (ICC > 0.98, SEM 0.59°-1.75°, MDC 1°-4°), with DI showing superior reliability. For human joint angles, device reliability ranged from moderate to excellent (ICC 0.697-0.975, SEM 1.93°-4.64°, MDC 5°-11° for inter-rater reliability; ICC 0.660-0.996, SEM 0.77°-4.06°, MDC 2°-9° for intra-rater reliability), with SA demonstrating superior reliability. Wider angle measurement however resulted in reduced device reliability. In conclusion, our study demonstrates that it is essential to assess measurement errors independently for standard and human joint angles. The DI is the preferred reference for standard angle testing, while the SA is recommended for human joint angle testing. Separate evaluations across the complete 0°-180° range offer valuable insights.

Indexed as

Arthrometry, ArticularMobile ApplicationsHumansRange of Motion, ArticularReproducibility of ResultsResearch Subjects

Identifiers

PMID38017058
PMCPMC10684565
OpenAlexW4389091298

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.