Evidence map›Paper›PMID 38016804›Full record

ArticleRadiation protection dosimetry2024

Assessment of organ doses, peak skin doses and effective doses in patients undergoing anterior cervical discectomy and fusion utilising VirtualDose-IR software.

Vasileios Metaxas, Christos Dimitroukas, Fotios Efthymiou, Harry Delis, George Gatzounis, Fotios Tzortzidis, Petros Zampakis, Andreas Theofanopoulos, Constantine Constantoyannis, George Panayiotakis

Open access · hybridAbstract read
In one paragraph

Article in Radiation protection dosimetry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 0 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Vasileios MetaxasDepartment of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.
Christos DimitroukasDepartment of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.ORCID 0000-0002-6009-4059
Fotios EfthymiouDepartment of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.
Harry DelisDepartment of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.
George GatzounisDepartment of Neurosurgery, University Hospital of Patras, 26504 Patras, Greece.ORCID 0000-0002-4022-6691
Fotios TzortzidisDepartment of Neurosurgery, University Hospital of Patras, 26504 Patras, Greece.
Petros ZampakisDepartment of Radiology, University Hospital of Patras, 26504 Patras, Greece.
Andreas TheofanopoulosDepartment of Neurosurgery, University Hospital of Patras, 26504 Patras, Greece.
Constantine ConstantoyannisDepartment of Neurosurgery, University Hospital of Patras, 26504 Patras, Greece.
George PanayiotakisDepartment of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.ORCID 0000-0002-4802-666X
University of Patras · GRGeneral University Hospital of Patras · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, the effect of patient- and procedure-related parameters on organ doses (ODs), peak skin dose (PSD) and effective dose (E) during anterior cervical discectomy and fusion (ACDF) was evaluated. Patient- and procedure-related parameters, as well as fluoroscopy time, kerma-area product (KAP), cumulative air-kerma (Kair) and incident Kair, were analysed for 50 ACDF procedures performed with a mobile C-arm. These parameters were inserted in VirtualDose-IR software implementing sex-specific and body mass index (BMI)-adjustable anthropomorphic phantoms to calculate OD, PSD and E. The BMI, gender and type of implants did not significantly affect KAP, incident Kair, PSD and E. However, the type of fusion significantly affected the E. The single fusions in C5/C6 resulted in significantly higher KAP, incident Kair and E than C4/C5 levels, while those performed in C6/C7 resulted in significantly higher E and PSD than C4/C5 levels. The thyroid, oesophagus and salivary glands received the largest doses in all groups studied. The BMI did not significantly affect ODs. The salivary glands absorbed significantly higher doses in males than females, while the extrathoracic region's dose significantly increased for multi- than single-level fusions. The fusions in C6/C7 resulted in significantly higher oesophagus and thyroid doses than C3/C4 and C4/C5 levels, as well as fusions performed in C5/C6 compared with C4/C5 levels. The data presented here could be used by the neurosurgeons as a comparator for future studies in optimising radiation protection during ACDF procedures in the operating theatre by keeping the ODs, PSD and E as low as reasonably practicable.

Indexed as

Cervical VertebraeDiskectomyFemaleFluoroscopyHumansMaleSoftware