Evidence map›Paper›PMID 38016115›Full record

ArticleJournal of the Chinese Medical Association : JCMA2024

Clinical application of ultrasound-guided totally implantable venous access ports implantation via the posterior approach of the internal jugular vein.

Minghai Wang, Linna Tang, Rongwei Xu, Shiyong Qin, Shuguang Zhang

Open access · hybridAbstract read
In one paragraph

Article in Journal of the Chinese Medical Association : JCMA, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Minghai WangDepartment of General Surgery, The First Affiliated Hospital to Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
Linna TangDepartment of Hospital Infection Control, The First Affiliated Hospital to Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
Rongwei XuDepartment of General Surgery, The First Affiliated Hospital to Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
Shiyong QinDepartment of General Surgery, The First Affiliated Hospital to Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
Shuguang ZhangDepartment of General Surgery, The First Affiliated Hospital to Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
Shandong Provincial QianFoShan Hospital · CNShandong First Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo determine the feasibility and safety of ultrasound-guided totally implantable venous access port (TIVAP) implantation via the posterior approach of the internal jugular vein (IJV).

methodsFrom September 2021 to August 2022, 88 oncology patients underwent ultrasound-guided implantation of TIVAPs via the posterior approach of the IJV for the administration of chemotherapy. The catheter tip was adjusted to be positioned at the cavoatrial junction under fluoroscopic guidance. Clinical data including surgical success, success rate for the first attempt, intraoperative, and postoperative complications were all collected and analyzed.

resultsAll patients underwent successful surgery (100%), whereby 58 were via the right IJV and 30 via the left IJV, and the success rate for the first attempt was 96.59% (85/88). The operation time was 20 to 43 minutes, with an average of 26.59 ± 6.18 minutes with no intraoperative complications. The follow-up duration ranged from 1 to 12 months (mean = 5.28 ± 3.07) and the follow-up rate was 100%. The rate of postoperative complications was 4.55% (4/88), including port-site infection in two cases, fibrin sheath formation in one case, and port flip in one case. No other complications were observed during follow-up.

conclusionUltrasound-guided TIVAP implantation via the posterior approach of the IJV is feasible, safe, and effective, with a low rate of intraoperative and postoperative complications. Not only was the curvature of the catheter device smooth, but patients were satisfied with the comfort and cosmetic appearance. Additionally, we could reduce the possible complications of pinching and kinking of the catheter by using this approach. Therefore, further large-sample, prospective, and randomized controlled trials are warranted.

Indexed as

Catheterization, Central VenousCatheters, IndwellingHumansJugular VeinsPostoperative ComplicationsProspective StudiesRetrospective StudiesUltrasonography, Interventional

Identifiers

PMID38016115
PMCPMC12718871
OpenAlexW4389074592

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.