Evidence map›Paper›PMID 38015319›Full record

ArticleJournal of experimental orthopaedics2023

Customized-individually-made origin® implants in total knee arthroplasty allow a reliable solution for accurate reproduction of planned implant positioning.

Martin Sajan, Mohamad K Moussa, Nicolas Lefèvre, Charles Payan, Eugénie Valentin, Alain Meyer, Yoann Bohu, Zeinab Khalaf, Olivier Grimaud, Antoinne Gerometta and 2 more

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Martin SajanHôpital de la Pitié Salpêtrière-AP-HP, 75013, Paris, France.
Mohamad K MoussaClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France. mhamadmoussa71976798@gmail.com.
Nicolas LefèvreClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Charles PayanHôpital Henri Mondor- AP-HP, 94000, Créteil, France.
Eugénie ValentinClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Alain MeyerClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Yoann BohuClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Zeinab KhalafClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Olivier GrimaudClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Antoinne GeromettaClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Alexandre HardyClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Frédéric KhiamiClinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
Clinique du Sport · FRHôpitaux Universitaires Henri-Mondor · FRSorbonne Université · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy and reproducibility of a patient-specific, customized individually made (CIM) total knee replacement (TKR) using the ORIGIN® prosthesis.

methodsThis was a prospective study conducted at a University Hospital from January 15, 2019, to April 30, 2021. The study included patients planned for an ORIGIN® CIM TKR procedure. Exclusion criteria included revision surgery, severe deformity, stiffness, or laxity. Evaluations were carried out using computed tomography scans performed 8 weeks preoperatively and 6 weeks postoperatively. The primary outcome measurements were the preoperative, planned, and postoperative CT scan alignment measurements including the Hip-Knee-Ankle (HKA) angle, mechanical Medial Distal Femoral articular surface Angle (mMDFA, distal alpha angle), Posterior Distal femoral articular surface angle (PDFA, posterior alpha angle), mechanical Medial Proximal Tibial articular surface Angle (mMPTA, beta angle) and posterior proximal tibial angle (PPTA). Secondary outcomes included the accuracy of implant positioning with percentage of outliers at 2° and 3°

resultsThe study encompassed 51 knees from 50 patients with mean age of 68.1 (SD = 8.89). The overall HKA angle deviated by -0.93° [95% CI: -1.45; -0.43], and the PDFA angle by -0.61° [95% CI: -1.07; -0.15], while the mMPTA exceeded planned values by 1.00° [95% CI: 0.57; 1.43]. The 3° outliers rate ranged from 3.9% for the mMPTA to 7.8% for the HKA alignment, with no outliers in mMDFA and PPTA. Similarly, the 2° outliers rate ranged from 15.7% for both the PDFA angle and mMPTA to 19.6% for the HKA alignment. The Bland-Altman plots further emphasized the precision of planned and post-operative angles across all measurements.

conclusionThe CIM TKR showed high accuracy and reproducibility, closely matching preoperative planning. The weakest accuracy at 3°-outliers is in the reproduction of the HKA alignment at 92.2% (range for all angle: 92.2-100%). Similarly, the weakest accuracy at 2°-outliers is in the reproduction of the HKA alignment at 80.4% (range for all angles: 80.4-92.2%).

Indexed as

Accuracy rateCustomized Individually Made TKRHKA alignmentImplant positioningOutliersPreoperative planningRadiological measurements

Identifiers

PMID38015319
PMCPMC10684845
OpenAlexW4389091825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.