ArticleJournal of neurosurgery. Case lessons2023
Rescue stenting after artery occlusion as a complication of an intrasaccular device-assisted coiling embolization: illustrative case.
Article in Journal of neurosurgery. Case lessons, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEndovascular embolization of wide-necked aneurysms can be challenging. The development of intrasaccular devices like the Contour has enabled us to approach these aneurysms effectively by reducing recanalization rates and eliminating the need for dual antiplatelet therapy, which is particularly beneficial in the case of ruptured aneurysms. Although complications from using these devices are rare, it is crucial to address them properly. In this case, the authors highlight how to manage artery thrombosis caused by device protrusion during aneurysm embolization. OBSERVATIONS: This report describes a complication in a male patient with a ruptured anterior communicating artery wide-necked aneurysm. Following Contour-assisted coiling of the aneurysm, a realignment of the detachable apex of the device occluded the A2 segment of the right anterior cerebral artery. After the failure of intra-arterial and intravenous tirofiban infusion as well as mechanical thrombectomy, a self-expanding open-cell stent was deployed in the involved vessel, achieving successful reperfusion. LESSONS: The Contour device has a detachable zone that can cause occlusion of the parent vessel after deployment. The use of a stent as a rescue maneuver may be useful if reperfusion of the vessel cannot be achieved through other methods such as aspiration or full-dose antiplatelet therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.