Volumetric MRI with sparse sampling for MR-guided 3D motion tracking via sparse prior-augmented implicit neural representation learning.

Lianli Liu, Liyue Shen, Adam Johansson, James M Balter, Yue Cao, Lucas Vitzthum, Lei Xing

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Lianli LiuDepartment of Radiation Oncology, Stanford University, Palo Alto, California, USA.
Liyue ShenDepartment of Electrical Engineering, Stanford University, Palo Alto, California, USA.
Adam JohanssonDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
James M BalterDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Yue CaoDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Lucas VitzthumDepartment of Radiation Oncology, Stanford University, Palo Alto, California, USA.
Lei XingDepartment of Radiation Oncology, Stanford University, Palo Alto, California, USA.
Stanford University · USUniversity of Michigan–Ann Arbor · US

Funding

Optimizing MRI for Radiation Therapy Treatment PlanningR01EB016079 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BALTER, JAMES M, CAO, YUE · 2013 to 2022
$3.1M
Dual Modality X-ray Luminescence CT for in vivo Cancer ImagingR01CA227713 · NCI · STANFORD UNIVERSITY · PI XING, LEI · 2019 to 2023
$2.9M
Radioluminescence dosimetry solution for precision radiation therapyR01CA223667 · NCI · STANFORD UNIVERSITY · PI XING, LEI · 2018 to 2022
$2.4M
Intraoperative integration of artificial intelligence during cystoscopic surgeryR01CA260426 · NCI · STANFORD UNIVERSITY · PI JOSEPH C LIAO, Lei Xing · 2022 to 2026
$2.3M
Leveraging deep learning for markerless motion management in radiation therapyR01CA256890 · NCI · STANFORD UNIVERSITY · PI XING, LEI · 2021 to 2025
$2.1M
Development of AI-Augmented quality assurance tools for radiation therapyR01CA275772 · NCI · STANFORD UNIVERSITY · PI Lei Xing · 2023 to 2026
$2.1M
NCI NIH HHS R01 CA223667NCI NIH HHS R01 CA227713NCI NIH HHS R01 CA256890NCI NIH HHS R01 CA260426NCI NIH HHS R01 CA275772NIBIB NIH HHS R01 EB016079NIH HHS 1R01CA223667NIH HHS 1R01CA227713NIH HHS 5R01CA256890NIH HHS 5R01CA260426NIH HHS NIH R01 EB016079
6 · The paper itself

Abstract

backgroundVolumetric reconstruction of magnetic resonance imaging (MRI) from sparse samples is desirable for 3D motion tracking and promises to improve magnetic resonance (MR)-guided radiation treatment precision. Data-driven sparse MRI reconstruction, however, requires large-scale training datasets for prior learning, which is time-consuming and challenging to acquire in clinical settings. PURPOSE: To investigate volumetric reconstruction of MRI from sparse samples of two orthogonal slices aided by sparse priors of two static 3D MRI through implicit neural representation (NeRP) learning, in support of 3D motion tracking during MR-guided radiotherapy.

methodsA multi-layer perceptron network was trained to parameterize the NeRP model of a patient-specific MRI dataset, where the network takes 4D data coordinates of voxel locations and motion states as inputs and outputs corresponding voxel intensities. By first training the network to learn the NeRP of two static 3D MRI with different breathing motion states, prior information of patient breathing motion was embedded into network weights through optimization. The prior information was then augmented from two motion states to 31 motion states by querying the optimized network at interpolated and extrapolated motion state coordinates. Starting from the prior-augmented NeRP model as an initialization point, we further trained the network to fit sparse samples of two orthogonal MRI slices and the final volumetric reconstruction was obtained by querying the trained network at 3D spatial locations. We evaluated the proposed method using 5-min volumetric MRI time series with 340 ms temporal resolution for seven abdominal patients with hepatocellular carcinoma, acquired using golden-angle radial MRI sequence and reconstructed through retrospective sorting. Two volumetric MRI with inhale and exhale states respectively were selected from the first 30 s of the time series for prior embedding and augmentation. The remaining 4.5-min time series was used for volumetric reconstruction evaluation, where we retrospectively subsampled each MRI to two orthogonal slices and compared model-reconstructed images to ground truth images in terms of image quality and the capability of supporting 3D target motion tracking.

resultsAcross the seven patients evaluated, the peak signal-to-noise-ratio between model-reconstructed and ground truth MR images was 38.02 ± 2.60 dB and the structure similarity index measure was 0.98 ± 0.01. Throughout the 4.5-min time period, gross tumor volume (GTV) motion estimated by deforming a reference state MRI to model-reconstructed and ground truth MRI showed good consistency. The 95-percentile Hausdorff distance between GTV contours was 2.41 ± 0.77 mm, which is less than the voxel dimension. The mean GTV centroid position difference between ground truth and model estimation was less than 1 mm in all three orthogonal directions.

conclusionA prior-augmented NeRP model has been developed to reconstruct volumetric MRI from sparse samples of orthogonal cine slices. Only one exhale and one inhale 3D MRI were needed to train the model to learn prior information of patient breathing motion for sparse image reconstruction. The proposed model has the potential of supporting 3D motion tracking during MR-guided radiotherapy for improved treatment precision and promises a major simplification of the workflow by eliminating the need for large-scale training datasets.

Indexed as

AbdomenMagnetic Resonance ImagingHumansImaging, Three-DimensionalMagnetic Resonance SpectroscopyMotionRespirationRetrospective Studiesdeep learningimage reconstructionmotion managementMR‐guided radiotherapy

Identifiers

PMID38014764
PMCPMC10994763
OpenAlexW4389098946

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.