ArticleRadiation research2024
Assessment of Cataract Risk after Diagnostic Head CT Scan Radiation Exposure in Ontario, Canada.
Article in Radiation research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Critical Review of Cataractogenesis and Lens Contouring in Radiation Oncology.Advances in radiation oncology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
Abstract
Ionizing radiation is one of the known risk factors for cataract development, however, there is still debate regarding the level of risk after low dose exposures. One of the largest sources of radiation exposure to the lens of the eye is diagnostic CT scans. The aim of this study was to examine whether ionizing radiation associated with head CT scans increases cataract risk in residents of Ontario, Canada. Data were collected from January 1, 1994 to December 31, 2015 (22 years) from anonymized Ontario Health Insurance Plan (OHIP) medical records for over 16 million subjects. A lens dose was estimated for each CT scan using the National Cancer Institute dosimetry system for CT (NCICT) program combined with Canada-specific CTDIvol data. Multivariate Cox proportional hazards analysis was performed with cataract extraction surgery as the primary outcome and lens dose as the main variable of interest, with inclusion of various medical and demographic covariates. Lag periods of 3, 5 and 7 years were incorporated. When lens dose was treated as a continuous variable, hazard ratios (per 100 mGy) ranged from 0.82 (0.80-0.84) to 1.10 (1.09-1.11) depending on the lag period. As a secondary analysis, when individuals were binned based on their total cumulative dose, no significant dose response pattern was observed in the low dose region. Overall, within the bounds of this study, the data do not support an increased risk of vision impairing cataracts after diagnostic head CT scan radiation exposure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.