Evidence map›Paper›PMID 38014146›Full record

ArticlemedRxiv : the preprint server for health sciences2023

Prosthetic Visual Acuity with the PRIMA System in Patients with Atrophic Age-related Macular Degeneration at 4 years follow-up.

Mmk Muqit, Y Le Mer, L Olmos de Koo, F G Holz, J A Sahel, D Palanker

Registry-linked trialOpen access · greenAbstract readPreprint
In one paragraph

Article in medRxiv : the preprint server for health sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03333954 (Feasibility Study of Compensation for Blindness With the PRIMA System in Patients With Dry Age Related Macular Degeneration), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03333954 nacompletednot on this map

Feasibility Study of Compensation for Blindness With the PRIMA System in Patients With Dry Age Related Macular Degeneration

TypeinterventionalSponsorScience CorporationRan2017 to 2024Enrolled5ConditionsDry Age-related Macular DegenerationArmsPRIMA Bionic Vision System
3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 7 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 6 institutions in 4 countries.

Mmk MuqitVitreoretinal Service, Moorfields Eye Hospital, London, UK.ORCID 0000-0003-1161-3956
Y Le MerDepartment of Ophthalmology, Fondation Ophtalmologique A. de Rothschild, Paris, France.
L Olmos de KooDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
F G HolzDepartment of Ophthalmology, University of Bonn, Germany.
J A SahelDepartment of Ophthalmology, Fondation Ophtalmologique A. de Rothschild, Paris, France.
D PalankerDepartment of Ophthalmology, Stanford University, Stanford, CA, USA.ORCID 0000-0002-0480-3025
Centre hospitalier national d'ophtalmologie des Quinze-Vingts · FRMoorfields Eye Hospital · GBStanford University · USUniversity of Bonn · DEUniversity of Pittsburgh · USUniversity of Washington · US

Funding

Photovoltaic Subretinal Prosthesis with High Pixel DensityR01EY027786 · NEI · STANFORD UNIVERSITY · PI PALANKER, DANIEL V · 2017 to 2021
$3.3M
NEI NIH HHS R01 EY027786
6 · The paper itself

Abstract

Objective: To assess the efficacy and safety of the PRIMA subretinal neurostimulation system 48-months post-implantation for improving visual acuity (VA) in patients with geographic atrophy (GA) due to age-related macular degeneration (AMD) at 48-months post-implantation. Design: First-in-human clinical trial of the PRIMA subretinal prosthesis in patients with atrophic AMD, measuring best-corrected ETDRS VA (Clinicaltrials.gov NCT03333954). Subjects: Five patients with GA, no foveal light perception and VA of logMAR 1.3 to 1.7 in their worse-seeing "study" eye. Methods: In patients implanted with a subretinal photovoltaic neurostimulation array containing 378 pixels of 100 μm in size, the VA was measured with and without the PRIMA system using ETDRS charts at 1 meter. The system's external components: augmented reality glasses and pocket computer, provide image processing capabilities, including zoom. Main Outcome Measures: VA using ETDRS charts with and without the system. Light sensitivity in the central visual field, as measured by Octopus perimetry. Anatomical outcomes demonstrated by fundus photography and optical coherence tomography up to 48-months post-implantation. Results: All five subjects met the primary endpoint of light perception elicited by the implant in the scotoma area. In one patient the implant was incorrectly inserted into the choroid. One subject died 18-months post-implantation due to study-unrelated reason. ETDRS VA results for the remaining three subjects are reported herein. Without zoom, VA closely matched the pixel size of the implant: 1.17 ± 0.13 pixels, corresponding to mean logMAR 1.39, or Snellen 20/500, ranging from 20/438 to 20/565. Using zoom at 48 months, subjects improved their VA by 32 ETDRS letters versus baseline (SE 5.1) 95% CI[13.4,49.9], p<0.0001. Natural peripheral visual function in the treated eye did not decline after surgery compared to the fellow eye (p=0.08) during the 48 months follow-up period. Conclusions: Subretinal implantation of PRIMA in subjects with GA suffering from profound vision loss due to AMD is feasible and well tolerated, with no reduction of natural peripheral vision up to 48-months. Using prosthetic central vision through photovoltaic neurostimulation, patients reliably recognized letters and sequences of letters,and with zoom it provided a clinically meaningful improvement in VA of up to eight ETDRS lines.

Indexed as

Age-related macular degenerationgeographic atrophyneuromodulationneurostimulationretinal prosthesissubretinal photovoltaic implantsubretinal stimulation microchipvisual prosthesis

Identifiers

PMID38014146
PMCPMC10680875
OpenAlexW4388626847

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.