Evidence map›Paper›PMID 38013761›Full record

ArticleSensors & diagnostics2023

Point-of-care therapeutic drug monitoring of tumour necrosis factor-α inhibitors using a single step immunoassay.

Eva A van Aalen, Ivar R de Vries, Eva T L Hanckmann, Jeannot R F Stevens, Thomas R Romagnoli, Luc J J Derijks, Maarten A C Broeren, Maarten Merkx

Open access · diamondAbstract read
In one paragraph

Article in Sensors & diagnostics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Eva A van AalenLaboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands m.merkx@tue.nl +31 40 247 4728.
Ivar R de VriesDepartment of Electrical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands.
Eva T L HanckmannLaboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands m.merkx@tue.nl +31 40 247 4728.
Jeannot R F StevensLaboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands m.merkx@tue.nl +31 40 247 4728.
Thomas R RomagnoliLaboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands m.merkx@tue.nl +31 40 247 4728.
Luc J J DerijksDepartment of Clinical Pharmacy and Pharmacology, Máxima Medical Center P.O. Box 7777 5500 MB Veldhoven The Netherlands.
Maarten A C BroerenLaboratory of Clinical Chemistry and Haematology, Máxima Medical Center P.O. Box 7777 5500 MB Veldhoven The Netherlands.
Maarten MerkxLaboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology P.O. Box 513 5600 MB Eindhoven The Netherlands m.merkx@tue.nl +31 40 247 4728.ORCID https://orcid.org/0000-0001-9484-3882
Eindhoven University of Technology · NLRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Therapeutic drug monitoring (TDM) of tumor necrosis factor-α (TNFα)-inhibitors adalimumab and infliximab is important to establish optimal drug dose and maximize treatment efficacy. Currently, TDM is primarily performed with ELISA techniques in clinical laboratories, resulting in a long sample-to-result workflow. Point-of-care (POC) detection of these therapeutic antibodies could significantly decrease turnaround times and allow for user-friendly home-testing. Here, we adapted the recently developed bioluminescent dRAPPID (dimeric Ratiometric Plug-and-Play Immunodiagnostics) sensor platform to allow POC TDM of infliximab and adalimumab. We applied the two best performing dRAPPID sensors, with limit-of-detections of 1 pM and 17 pM, to measure the infliximab and adalimumab levels in 49 and 40 patient serum samples, respectively. The analytical performance of dRAPPID was benchmarked with commercial ELISAs and yielded Pearson's correlation coefficients of 0.93 and 0.94 for infliximab and adalimumab, respectively. Furthermore, a dedicated bioluminescence reader was fabricated and used as a readout device for the TDM dRAPPID sensors. Subsequently, infliximab and adalimumab patient serum samples were measured with the TDM dRAPPID sensors and bioluminescence reader, yielding Pearson's correlation coefficients of 0.97 and 0.86 for infliximab and adalimumab, respectively, and small proportional differences with ELISA (slope was 0.97 ± 0.09 and 0.96 ± 0.20, respectively). The adalimumab and infliximab dRAPPID sensors, in combination with the dedicated bioluminescence reader, allow for ease-of-use TDM with a fast turnaround time and show potential for POC TDM outside of clinical laboratories.

Identifiers

PMID38013761
PMCPMC10633107
OpenAlexW4386431782

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.