ArticleJournal of orthopaedic surgery and research2023
Finite element analyses of three minimally invasive fixation techniques for treating Sanders type II intra-articular calcaneal fractures.
Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Different screw configurations for treating Sanders type IIB intra-articular calcaneal fractures: a finite element analysis.BMC musculoskeletal disorders · 2026Article
- Biomechanical comparison of frame configuration screw fixation and conventional plate fixation for Sanders type iii fractures: a finite element analysis.BMC surgery · 2026Article
- Treatment Options in Managing Infections Following Calcaneal Fractures: A Systematic Review.Life (Basel, Switzerland) · 2026Review
- Safe and Accurate Sustentaculum Screw Placement in Minimally Invasive Surgery for Calcaneal Fractures: The "Sustentaculum View" Technique.Journal of clinical medicine · 2026Article
- Finite element analysis and clinical application of percutaneous sustentaculum tali screw fixation for Sanders type II and III calcaneal fractures.Scientific reports · 2026Article
- A quantitative three-dimensional analysis of posterior facet displacement in Sanders Type II and III intra-articular calcaneal fractures.Frontiers in surgery · 2026Article
- Article
- Comparing the stability of a novel h-shaped bone plate and commercial endosteal plating systems in hallux valgus correction.Journal of orthopaedic surgery and research · 2025Article
- Does Grafting Matter in Surgically Treated Calcaneal Fractures? A Retrospective Analysis.Sisli Etfal Hastanesi tip bulteni · 2025Article
- Arthroscopic-assisted reduction and fixation of calcaneal fractures using sustentaculum tali and medial wall screws.Frontiers in surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
BACKGROUND AND
objectiveCalcaneal Sanders type II or III fractures are highly disabling with significant burden. Surgical treatment modalities include open reduction and internal fixation (ORIF) techniques and a variety of minimally invasive surgical (MIS) approaches. ORIF techniques are associated with complications and traditional MIS techniques need extensive intraoperative fluoroscopic procedures. The present study aims to investigate the effects of three different minimally invasive internal fixation (MIIF) techniques used to treat Sanders type II intra-articular calcaneal fractures using finite element analyses.
methodsA 64-row spiral computed tomography scan was used to observe the calcaneus of a healthy adult. The scanning data were imported into Mimics in a DICOM format. Using a new model of a Sanders type II-B intra-articular calcaneal fracture, three minimally invasive techniques were simulated. Technique A involved fixation using an isolated minimally invasive locking plate; Technique B used a minimally invasive locking plate with one medial support screw; and Technique C simulated a screw fixation technique using four 4.0-mm screws. After simulating a 640-N load on the subtalar facet, the maximum displacement and von Mises stress of fragments and implants were recorded to evaluate the biomechanical stability of different fixation techniques using finite element analyses.
resultsAfter stress loading, the maximum displacements of the fragments and implants were located at the sustentaculum tali and the tip of sustentaculum tali screw, respectively, in the three techniques; however, among the three techniques, Technique B had better results for displacement of both. The maximum von Mises stress on the fragments was < 56 Mpa, and stress on the implants using the three techniques was less than the yield strength, with Technique C having the least stress.
conclusionAll three techniques were successful in providing a stable fixation for Sanders type II intra-articular calcaneal fractures, while the minimally invasive calcaneal locking plate with medial support screw fixation approach exhibited greater stability, leading to improved enhancement for the facet fragment; however, screw fixation dispersed the stress more effectively than the other two techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.