An extended bore length solid-state digital-BGO PET/CT system: design, preliminary experience, and performance characteristics.

John A Kennedy, Tala Palchan-Hazan, Quentin Maronnier, Olivier Caselles, Frédéric Courbon, Moshe Levy, Zohar Keidar

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. [BMJ open · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

John A KennedyDepartment of Nuclear Medicine, Rambam Health Care Campus, P.O.B. 9602, 3109601, Haifa, Israel. j_kennedy@rambam.health.gov.il.ORCID 0000-0002-2043-4397
Tala Palchan-HazanDepartment of Nuclear Medicine, Rambam Health Care Campus, P.O.B. 9602, 3109601, Haifa, Israel.
Quentin MaronnierMedical Imaging Department, Oncopole Claudius Regaud, Toulouse, France.ORCID 0000-0002-2266-9122
Olivier CasellesMedical Imaging Department, Oncopole Claudius Regaud, Toulouse, France.ORCID 0000-0002-5404-5066
Frédéric CourbonMedical Imaging Department, Oncopole Claudius Regaud, Toulouse, France.
Moshe LevyGE Healthcare, Tirat HaCarmel, Tirat HaCarmel, Israel.
Zohar KeidarDepartment of Nuclear Medicine, Rambam Health Care Campus, P.O.B. 9602, 3109601, Haifa, Israel.ORCID 0000-0002-6057-778X
Institut Claudius Regaud · FRRambam Health Care Campus · ILTechnion – Israel Institute of Technology · ILTirat Carmel Mental Health Center · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeA solid-state PET/CT system uses bismuth germanium oxide (BGO) scintillating crystals coupled to silicon photomultipliers over an extended 32 cm axial field-of-view (FOV) to provide high spatial resolution and very high sensitivity. Performance characteristics were determined for this digital-BGO system, including NEMA and EARL standards.

methodsSpatial resolution, scatter fraction (SF), noise equivalent count rate (NECR), sensitivity, count rate accuracy, and image quality (IQ) were evaluated for the digital-BGO system as per NEMA NU 2-2018, at 2 sites of first clinical install. System energy resolution was measured. Bayesian penalized-likelihood reconstruction (BPL) was used for IQ. EARL Standards 2 studies were reconstructed by BPL combined with a contrast-enhancing deep learning algorithm. An Esser PET phantom was evaluated. Three patient examples were obtained with low-dose radiotracer activity: 2 MBq/kg of [

resultsNEMA sensitivity was 47.6 cps/kBq at the axial center. Spatial resolution at 1 cm from the center axis was ≤4.5 mm (filtered back projection) and ≤3.8 mm (ordered subset expectation maximization). SF was 35.6%, count rate accuracy was 2.16%, and peak NECR was 485.2 kcps at 16.9 kBq/mL. Contrast for IQ was 61.1 to 90.7% (smallest to largest sphere) with background variations from 7.6 to 2.1%, and a "lung" error of 4.7%. The average detector energy resolution was 9.67%. Image quality for patient scans was good. EARL Standards 2 criteria were robustly met and Esser phantom features ≥4.8 mm were resolved at 2 min per bed position.

conclusionA solid-state 32 cm axial FOV digital-BGO PET/CT system provides good spatial and energy resolution, high count rates, and superior NEMA sensitivity in its class, enabling fast clinical acquisitions with low-dose radiotracer activity.

Indexed as

BismuthGermaniumPositron-Emission TomographyPositron Emission Tomography Computed TomographyBayes TheoremHumansPhantoms, ImagingReference StandardsBismuthbismuth germanium oxideGermaniumBGOBismuth germanium oxideLong axial field-of-viewPET/CTSolid-state

Identifiers

PMID38012446
OpenAlexW4389082590

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.