An extended bore length solid-state digital-BGO PET/CT system: design, preliminary experience, and performance characteristics.
Article in European journal of nuclear medicine and molecular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 10 citations in OpenAlex.
- Evaluation of the time‑of‑flight-enhanced deep learning image reconstruction method inPhysical and engineering sciences in medicine · 2026Article
- Evaluation of deep learning-based reconstruction models on non-TOF BGO PET/CT: impact of acquisition times and BSREM penalization factors on lesion detectability and SNR.EJNMMI physics · 2026Article
- [BMJ open · 2026Article
- Deep learning-enhanced digital-BGO versus TOF PET/CT: comparative assessment of detection, quantitation, and overall image quality.EJNMMI physics · 2025Article
- Evaluation of a digital bismuth germanium oxide PET/CT system according to the Japanese brain tumor phantom test forPhysical and engineering sciences in medicine · 2025Article
- Effects of a deep learning-based image quality enhancement method on a digital-BGO PET/CT system forEJNMMI physics · 2025Article
- AI-based automatic patient positioning in a digital-BGO PET/CT scanner: efficacy and impact.EJNMMI physics · 2025Article
- Assessing the deep learning based image quality enhancements for the BGO based GE omni legend PET/CT.EJNMMI physics · 2024Article
- Monte Carlo simulation of the system performance of a long axial field-of-view PET based on monolithic LYSO detectors.EJNMMI physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeA solid-state PET/CT system uses bismuth germanium oxide (BGO) scintillating crystals coupled to silicon photomultipliers over an extended 32 cm axial field-of-view (FOV) to provide high spatial resolution and very high sensitivity. Performance characteristics were determined for this digital-BGO system, including NEMA and EARL standards.
methodsSpatial resolution, scatter fraction (SF), noise equivalent count rate (NECR), sensitivity, count rate accuracy, and image quality (IQ) were evaluated for the digital-BGO system as per NEMA NU 2-2018, at 2 sites of first clinical install. System energy resolution was measured. Bayesian penalized-likelihood reconstruction (BPL) was used for IQ. EARL Standards 2 studies were reconstructed by BPL combined with a contrast-enhancing deep learning algorithm. An Esser PET phantom was evaluated. Three patient examples were obtained with low-dose radiotracer activity: 2 MBq/kg of [
resultsNEMA sensitivity was 47.6 cps/kBq at the axial center. Spatial resolution at 1 cm from the center axis was ≤4.5 mm (filtered back projection) and ≤3.8 mm (ordered subset expectation maximization). SF was 35.6%, count rate accuracy was 2.16%, and peak NECR was 485.2 kcps at 16.9 kBq/mL. Contrast for IQ was 61.1 to 90.7% (smallest to largest sphere) with background variations from 7.6 to 2.1%, and a "lung" error of 4.7%. The average detector energy resolution was 9.67%. Image quality for patient scans was good. EARL Standards 2 criteria were robustly met and Esser phantom features ≥4.8 mm were resolved at 2 min per bed position.
conclusionA solid-state 32 cm axial FOV digital-BGO PET/CT system provides good spatial and energy resolution, high count rates, and superior NEMA sensitivity in its class, enabling fast clinical acquisitions with low-dose radiotracer activity.