Trial reportCardiovascular and interventional radiology2024
A Prospective Multicenter Randomized Controlled Trial for Comparing Drug-Coated and Conventional Balloon Angioplasty in Venous Anastomotic Stenosis of Hemodialysis Arteriovenous Grafts.
Trial report in Cardiovascular and interventional radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 syntheses or guidelines pooled it, 7 citations in OpenAlex.
- Comparison of Drug-Coated Balloon versus Plain Balloon Angioplasty for the Treatment of Arteriovenous Fistula Stenosis: A systematic review and meta-analysis of randomized controlled trials.Cardiovascular and interventional radiology · 2026Pooled it
- Efficacy of drug-coated balloon versus uncoated balloon for dysfunctional dialysis access: a systematic review and meta-analysis.Clinical and experimental nephrology · 2025Pooled it
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 5 institutions in 1 country.
Funding
Abstract
purposeTo evaluate the efficacy and safety of drug-coated balloon angioplasty compared to conventional balloon angioplasty in the treatment of dysfunctional arteriovenous grafts. MATERIALS AND
methodsThis prospective, multicenter, randomized clinical trial enrolled 190 patients with venous anastomotic stenosis in arteriovenous grafts at five participating hospitals. During pre-dilation, 4 patients dropped out due to ruptures requiring further treatment (n = 2) and residual stenosis of > 30% (n = 2). On successful pre-dilation with a 7 mm conventional balloon, patients were randomized to undergo either a 7 mm drug-coated balloon (n = 94) or conventional balloon angioplasty (n = 92). The primary out-come measure was target lesion primary patency at 3 and 6 months. The secondary out-come measures included target lesion primary patency at 12 months and access circuit primary patency at 6 and 12 months, clinical and technical success rates, and 12-month mortality differences between the groups.
resultsThe target lesion primary patency and access circuit patency rates at 3 and 6 months were significantly higher in drug-coated balloon angioplasty group as compared to conventional balloon angioplasty group. The technical and clinical success rates were 100% for both the groups. As a procedure-related complication, anastomotic site rupture occurred during pre-dilation in 4 cases. The number of deaths during the 12-month follow-up was one for each group. The number of early thrombotic events (at < 3 months) was significantly higher in the drug-coated balloon group (p = 0.002).
conclusionDrug-coated balloon angioplasty was more effective and safer for the treatment of dysfunctional arteriovenous grafts compared to conventional balloon angioplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.